Standalone operation with firmware option E300 V4
72
k4evo707en-2012-07
7.9.2.2 INI reset with programmer 1460
Task
LED Compact
Reader
LED registration
unit/illumination unit
1. Connect the programmer to the registration unit/RFID antenna
via the air interface, or the programming cable to the control unit
State LED goes out Lamp goes out,
1x short beep,
LED briefly flashes green
twice
2. Present programming Master to registration unit/RFID antenna
(actuator is now in programmer mode until the actuator times out
or the programmer breaks the connection)
1x short beep
3. Menu Actuator => INI reset => Yes
2x short beeps
4. Compact Reader is in operation again
1x short beep, LED briefly
flashes green twice (since
programmer is still
connected)
5. Use programmer to set the required configuration data, see
Chapter/Page
- Access point ready for bookings again
6. Remove programmer and wait for timeout to elapse
State LED lights up
again or flashes
Green or not lit
7.9.2.3 INI reset with programming Master (firmware option E300 V4)
Task
LED Compact
Reader
LED registration
unit/illumination unit
1. Hold programming Master (admin Master) at registration
unit/RFID antenna
Green LED starts to light
up
2. The reset is performed after 10 s (all authorizations are deleted,
admin Master is retained)
2x short beeps,
green LED remains lit
constantly
3. The INI reset is performed after 15 s, after which you should
remove the programming Master from the registration unit/RFID
antenna
State LED goes out 2x short beeps,
green LED goes out
4. Compact Reader is in operation again
State LED lights up
again or flashes
Green or not lit
5. Use programmer to set the required configuration data,
see Chapter 7.9.4/Page 75
- Access point ready for bookings again