Standalone operation with firmware option E300 V4
k4evo707en-2012-07
69
7.5
INI reset or firmware update with DIP switch 6
DIP switch 6 is used to activate the factory reset or firmware update.
DIP switch
Meaning
6 OFF
Deactivated
6 ON
Activated
INI reset, see description in Chapter 7.9.2/Page 71
Firmware update, see description in Chapter 7.9.3/Page 73
7.6 Antenna
adaptation
The slide switch (8) can be used to calibrate the antenna for mounting on metallic or non-metallic
bases.
Always
put the slide switch in the
Air
position, except when using a metallic base. The slide switch
is set to the
Air
position on delivery (default).
Position Meaning
In
Air
position for a non-metallic base;
(default)
In
Metal
position for a metallic base
7.7 LED
display
Displays the access decision and operating state by means of the central light symbol (red/green)
and an acoustic signal transmitter (buzzer).
Error correction tips can be found in Chapter 9/Page 79.
The relevant chapters contain descriptions of signaling during a factory reset and firmware update.
Signaling (default)
Meaning
Access signal
Green goes on briefly and 1x short beep
Flashing red/intermittent beep
Access authorized/Access allowed
Access not authorized
Operating state
Off
Red on
Ready for booking
Access point blocked
Air Metal