12
fInal InsTallaTIon
Warning:
Failure to verify that the lock is operational may cause a lockout condition.
1. Open the lock using the factory combination. (See Page 13.) Leave the bolt in
the fully retracted position.
2. Record the 8-digit lock serial number in a secure location if you are the end
user. If you are not the end user, allow the end user to remove the serial number
sticker from the back of the lock when the container has been placed in use.
3. Make sure the bolt is fully retracted.
4. Tighten the spindle screw to the torque specifications. (See Page 1.)
InsTallaTIon CompleTIon CheCKlIsT
1� Does the dial turn freely without scraping or binding?
2� Have all screws been securely tightened?
3� The dial clutch should provide a slip torque of 7 to 25 inch pounds�
4� Operate the lock using the preset factory combination of 50-25-50� See the
following section:
OPEN AND CLOSE THE X-10�
figure 25 - 5-sided flat spring
in dial
figure 26 - apply pressure to dial