background image

1

Lock Modes

A lock is shipped from the factory with default lock “setup” values and a pre-set PIN
for locking and unlocking the lock. This is referred to as 

Factory Mode

.

The lock is shipped with a default factory 

Super Master User PIN

 that can be set

(i.e., changed) when the lock is in Factory Mode. Once the Super Master User PIN is
set, the Super Master User combination can be used to shelve the lock in the event
that the Master User combination is lost. Refer to the 

Super Master Operations

(Document # 3109.017) for more detail.

WARNING:

The setting of the Super Master User PIN is optional, however, if you do

not set the Super Master User PIN before setting the 

Master

 User PIN, all

Super Master User capabilities will be permanently lost.

The lock is removed from Factory Mode when the Master User PIN gets changed.
To remove a lock from an operational mode, one can “shelve” the lock which places
it in 

Shelved Mode

Most

 lock values are returned to the factory default. Refer to the

Shelve Lock operation for more detail.

Personnel Classifications

There are three different classifications of lock personnel:

Master User 

- The 

Master

 User performs the initial lock setup activities and can also

shelve the lock. There is a maximum of one 

Master

 User per lock. The 

Master

 User

combination will also lock and unlock the lock.

Manager User

 - A user added by the Master User. A Manager User can lock and unlock

the lock. A Manager User can also retrieve reporting data from the lock if authorized to
do so by the Master User.

Lock User

 - A user who can take temporary ownership of a locker by setting a combina-

tion to lock and unlock the lock.

There can be a maximum of 126 users who can open this lock at specific times:

There can be a maximum of 

one Master User and 124 Manager Users

, programmed

and capable of accessing the lock at any given time.

There can be a maximum of 

one Lock User

 (not including the Master or Manager users)

programmed and capable of accessing the lock at any given time.

Document Number 3110.017  Rev. A2 - 09/07

UNICON

TM

 CL SERIES

M

ODEL

 CL10

A

DMINISTRATIVE

 O

PERATING

 I

NSTRUCTIONS

Содержание Unicon CL Series

Страница 1: ... to the factory default Refer to the Shelve Lock operation for more detail PersonnelClassifications There are three different classifications of lock personnel Master User The Master User performs the initial lock setup activities and can also shelve the lock There is a maximum of one Master User per lock The Master User combination will also lock and unlock the lock Manager User A user added by t...

Страница 2: ...s Combination The Lock User Access Combination is a 4 7 digit variable length combination that is set as each new Lock User takes ownership of the unit locker cabinet etc that needs to be secured The access combination can then be used to lock and unlock the lock until the current Lock User relinquishes ownership of the lock by leaving it in an open state and a new Lock User sets a new access comb...

Страница 3: ...iter for a combination 4 7 digits when a new Lock User combination is being set Once the yellow light appears it will stay on until the next key is selected or until the operation times out 15 seconds Please note the following operational differences based on the type of bolt you have installed Dead Bolt Manual Locking Technology There is a locked position and an unlocked positon for the knob on t...

Страница 4: ...or does not fire motor fire error the lock will respond with one green flash G and a beep to indicate that a valid combination has been entered but will then display three red flashes R R R with simultaneous beeps to indicate an error firing the motor A low battery condition is indicated by ten fast yellow flashes after a valid combination has been entered Normal operation and responses occur afte...

Страница 5: ...D for the lock model followed by the factory pre set PIN for that User ID will lock or unlock the lock Lock the Lock Master Manager Pre Set 1 If necessary turn the lock knob counter clockwise CCW to the locked position 2 Press and hold the key until the yellow light Y displays 3 Enter any valid three digit User ID for the lock model followed by the default factory PIN for the User ID For User ID 1...

Страница 6: ... Using the Lock User Pre Set Combination Your lock has been shipped so that the factory pre set access combination for the Lock User will lock or unlock the lock Lock the Lock Lock User Pre Set 1 If necessary turn the lock knob counter clockwise CCW to the locked position 2 Enter the default factory access combination of 5525 for the Lock User 3 Press and hold until yellow light Y displays If the ...

Страница 7: ... used to shelve the lock in the event that the Master User combination is lost Warning The setting of the Super Master User PIN is optional however if you do not set the Super Master User PIN before setting the Manager User PIN all Super Master User capabilities will be permanently lost If you do not wish to define a Super Master User combination for your lock proceed to the following page to comp...

Страница 8: ...ter the Master User combination G R 3 Enter a four digit number for the lock ID G R 4 Enter the number again for verification G R G R Toggle Sound On Off The Master User can toggle the sound on or off If on one beep sounds each time the lock LED flashes Note The default value for the lock sound is on This toggle can be changed at any time except when the lock is in shelved mode or when the lock is...

Страница 9: ...ain for verification G R G R Lock Startup Operations With the lock set up you are now ready for startup operations The following opera tions should be performed to enable full capabilities of the lock The instructions for performing these operations are located in the following Lock Operations section of the manual Master User 1 Add Manager User s to the lock Manager User s 1 Change default user P...

Страница 10: ... been added 6 Enter 111 to end the operation G R G R Note The default PIN assigned to a new Manager User ID is 55255 This default PIN must be changed by the User before any lock operations can be per formed Refer to the Change PIN section for instructions on changing a User PIN Delete Manager User s Note A Manager User can only be deleted by the person who created the User i e the Master User 1 Pr...

Страница 11: ...e audit record is written at this point followed by a lock close audit record if the knob is in the locked position If the knob is not fully turned CCW to the locked position the long red light R will not display at the end of the operation and the lock close record will not be written Shelve Lock using Master User Combination To remove a lock from an operational mode you can shelve the lock This ...

Страница 12: ... 5 Press Y G long G long R Note A combination locked state audit record is written at this point followed by a lock close audit record if the knob is in the locked position If the knob is not fully turned CCW to the locked position the long red light R will not display at the end of the operation and the lock close record will not be written Unlock with Lock User Access Combination 1 Enter the 4 7...

Страница 13: ... OFF Reporting Capabilities Users Date Time Note The Program Lock operation requires a teal colored blue green programming key fob that has been properly prepared at the PC using the Unicon CL Series Soft ware To program the lock complete the following steps 1 Press Y and then 2 G R 2 Enter the Master User combination Short red flashes with beeps R begin to display From the time these flashes begi...

Страница 14: ... teal colored programming key fob has been initialized to add and delete users rather than program the lock To Add Delete Users perform Steps 1 3 in the previous Program Lock section Upload Time The current time can be retrieved from the PC using the Unicon CL Series Software and then uploaded to the lock via a programming key fob Note The Upload Access Schedules operation requires a teal colored ...

Страница 15: ...ing Note The retrieve audit records operation requires a red reporting key fob that has been initialized using the PC software to retrieve audit records When an audit is retrieved it will overwrite any previously existing audit data that is in the key fob 1 Press Y and then 2 G R 2 Enter the combination Short red flashes with beeps R begin to display From the time these flashes begin you have 20 s...

Страница 16: ...ton KY 40508 USA Phone 859 253 4744 FAX 859 255 2655 Technical Support 800 950 4744 www kaba mas com 4 Return the key fob to the Unicon CL Series Software PC to be read Refer to the software documentation for instructions on reading the reporting key Retrieve User Table The lock s User information reporting feature will allow retrieval of status information for all administrative users in the lock...

Отзывы: