NETCOM6P Installation Guide
3
Install NETCOM Program Tool Utility Software
Each NETCOM6P that you are installing must be programmed with the NETCOM Program
Tool Utility software. Ensure you have the latest NETCOM Program Tool Utility software
installed which is on the enclosed CD, otherwise you may encounter communication
difficulties. You will require a PC or laptop that has a direct serial connection to the
CIM/NETCOM6P to program the device. To install the NETCOM Program Tool Utility
software, load the Keyscan Utilities & Drivers CD into the CD-ROM drive. The utility auto-
starts. Follow the on-screen prompts.
Connection Diagrams
Connection diagrams are on the succeeding pages of the guide as outlined:
See Figures 1—4 for temporary serial programming connections.
See Figures 5—6 for permanent network connections.
Steps to Install a NETCOM6P with a CIM
1.
Mount the NETCOM6P in the socket on the CIM as shown below. Press down so the
standoffs secure the NETCOM6P to the CIM circuit board. Do not change the
orientation of the standoffs.
TD1
RD1
TD2
RD2
GND
RTS
CTS
GND
RTS
CTS
B3 B2 B1 B0
Diag
J2
RESET
-
CAN2
+
EGND
-
CAN1
+
GND
V +
(+12V)
SCKT1
PC106x
J1
J7
J8
J6
J5
CAN2
CAN1
1
2 1
2
1
2
1
2
Rx - COM
COM
CAN
CAN - Tx
J3
J4
J9
J12
Power
Good
COM1
COM2
HDR1
J10
J11
Fault
(Flashing)
RJ45
Terminal
Jack
RESET
NETCOMP
Standoffs
NETCOMP
CIM
Standoff
- correct
mounting
orientation
Standoff
Program Mode
Jumper ON J12
KI-00466E-04-13
2.
Mount the CIM/NETCOM6P in its designated location in the metal enclosure.
As an option, the NETCOMP can be programmed off-site before installation
providing you have a 12 VDC power supply that can be connected to the CIM’s
TB4 power terminal. See figures 2 and 4.
3.
On the CIM circuit board, place a jumper on J12.
4.
Connect the ribbon cable from the HDR1 terminal on the CIM circuit board to the H2
terminal on the control board. See figures 1 and 3. The H2 terminal provides power
for programming the NETCOMP.
5.
Ensure the control board has power.
6.
Connect the RS-232 serial cable from the laptop or PC to the COM2 terminal block on
the CIM circuit board.
7.
Turn on the laptop or PC connected to the CIM circuit board.
Continued on the next page…