Instruction Manual - G85
22
6.7 St.St
The St.St (Start Set) option is the
timer function
for the
heat.
By using this option, time can be saved as the G85 can be ready for use before
procedures start in the morning.
Note
This function will only work correctly if the clock is set.
Follow these steps to navigate in the St.St option.
Action
Key
Display
Press and hold UP+DOWN key for
3 seconds to enter the menu.
The menu "UNIT" will appear in
the display.
Press key DOWN until the option
"St.St" appears in the display.
Press and hold setpoint key to
change values.
While holding the setpoint key,
press either the arrow UP to
change minutes or arrow DOWN
key to change the hour.
When the time is set, let go of the
setpoint
Press and hold UP+DOWN key for
3 seconds to exit the menu.
Note
If the function Heat is set, a dot will light up in the right side of display
.
St.St is connected with HEAT. It must be chosen when the timer starts. To turn the heater
on, please see section 6.8.
WARNING Always make sure when the timer function is being used, that the heated area
is clear of any objects that might be damaged by the heat or adversely
affected by it in way.
Caution should always be exercised when a heated area is turned on without
any supervison.