5
[REMOTE/LOCAL] switch
This switch is used to select how BR-HD50 is
to be operated.
LOCAL
: Use this setting if BR-HD50 is to
be controlled with the key opera-
tion of the unit.
REMOTE
: Use this setting to control this unit
using the REMOTE terminal,
SERIAL REMOTE terminal, or
IEEE1394 terminal.
Memo
z
Select to enable/disable operation with the
REMOTE terminal, using REMOTE SEL 9P on
the REMOTE [1/2] Menu screen.
z
To control BR-HD50 with the SERIAL
REMOTE terminal or IEEE1394 terminal, this
switch setting can be set up with REMOTE
SEL SERIAL or REM SEL HDV/DV in the
REMOTE [1/2] Menu screen. (
X
Page 70)
z
If it is set to REMOTE, the buttons that can be
operated from the unit are selectable from
LOCAL FUNCTION in the REMOTE [1/2]
Menu screen.
6
[INPUT SELECT] switch
This switch is used to select input signals.
HDV/DV
: Inputs IEEE1394 terminal HDV sig-
nals or DV signals.
The
8
IEEE1394 switch needs to
be set, according to whether the
video format is HDV or DV.
LINE
: For inputting the composite images
of the LINE IN terminal and analog
audio signals.
Y/C
: For inputting the Y/C separate
video signal of the Y/C IN terminal
and analog audio signals.
Note
z
Switching is invalid during recording.
z
Switching this switch during playback may
briefly cut off the audio.
7
[COUNTER] switch
Switches the displayed information on the
9
counter display and the monitor counter dis-
play.
CTL
: It displays the counter in hour, minute,
second and frame based on CTL (con-
trol signal).
TC
: It displays the time code data.
UB
: It displays the user’s bit (UB).