E-82
OTHERS
Troubleshooting (continued)
Symptom
Action
Cannot record HDV signals from
the IEEE1394 terminal.
• Is the IEEE1394 switch on the front panel set correctly?
To record HDV signals, set this to HDV.
• Is the HD signal format set correctly?
Match the 60/50 SEL setting in the SYSTEM [2/2] Menu
screen to the input HDV signal format. (
X
Page 40)
Cannot record DV signals from the
IEEE1394 terminal.
Is the IEEE1394 switch on the front panel set correctly?
To record DV signals, set this to DV.
No HD signal is output from the
HDMI OUT or COMPONENT OUT
terminal.
Is the HD signal format set correctly?
Match the 60/50 SEL setting in the SYSTEM [2/2] Menu screen
to the HD signal format. (
X
Page 40)
HDMI OUT terminal video does not
display on the monitor.
Is the monitor compatible with video from the HDMI OUT termi-
nal?
Check the monitor specifications.
To automatically set the HDMI OUT terminal video to the video
format for the connected equipment (monitor), set MONITOR
SELECT to HDMI[A] in the VIDEO Menu screen.
No signal is output from the
IEEE1394 terminal during play-
back.
• Is the IEEE1394 switch on the front panel set correctly?
Match the IEEE1394 switch setting to the playback tape
recording format.
• When playing a tape recorded in HDV format, check that the
HD signal format setting is correct. (
X
Page 40)
Содержание BR-HD50U - Compact HDV/DV Format Video Recorder
Страница 91: ......