E-99
Symptom
Action
No power
Unable to record.
The operation buttons of BR-
DV6000 do not work.
Editing cannot be controlled
even after the REMOTE/LOCAL
switch is set to REMOTE.
Noise is produced on the
playback video.
Playback sound interrupted.
Time codes are not correctly
recorded during DV signal input.
Unable to turn on the power with
the OPERATE button.
Serial remote control does not
function.
Unable to operate BR-DV6000
with the DV terminal.
When the power is turned on,
the unit goes into the REC or
PLAYBACK mode.
Is the AC adapter correctly connected?
Is the slide of the cassette tape turned to “REC”?
Set it to “REC” if it is at the “SAVE” position.
Is OPERATION LOCK of the SYSTEM (2/2) menu set to ON?
Set it to OFF if the operation buttons are to be used.
For REMOTE, select the buttons that can be operated with the
LOCAL FUNCTION Menu.
To control with RS-422A, set REMOTE SEL 9-PIN in the RE-
MOTE (1/2) Menu screen to “ON”.
To control with the JVC bus, set REMOTE SEL JVC to “ON”.
• The tape is damaged.
Replace the tape.
• The head is dirty.
Clean it with the specified head-cleaning tape. (Page 8)
Is TC DUPLICATE in the TC/UB/CLOCK (1/2) Menu screen
correctly set up?
Isn’t the REMOTE/LOCAL switch set to REMOTE when LO-
CAL FUNCTION in the REMOTE Menu screen is not set to
ALL KEYS?
Isn’t REMOTE SEL SER in the REMOTE (1/2) Menu screen
set to OFF?
For serial remote control, set it to ON or LOC+REM.
Isn’t REMOTE SEL DV in the REMOTE (1/2) Menu screen set
to OFF?
To operate with the DV terminal, set it to ON or LOC+REM.
The TIMER switch on the rear panel is set to REC or PLAY.
Check the setting of the TIMER switch before turning on the
power.