E-31
●
Connecting to a monitor TV
A monitor TV can be connected to the AUDIO
MONITOR OUT terminal.
The sound output from the AUDIO MONITOR
OUT terminal is monaural.
• The volume is adjusted through the monitor
TV.
• The output channel can be selected with the
AUDIO MONITOR switch on the front panel
(Refer to the following table).
AUDIO MONITOR switches and output
channels of AUDIO OUTPUT/PHONES
In the following cases, the output channels from
the AUDIO MONITOR OUTPUT/PHONES termi-
nal vary according to the setting of the AUDIO
MONITOR switch and the AUDIO OUTPUT switch.
The table below shows the channels.
• During playback of tapes recorded in the
32kHz audio mode.
• During audio dubbing.
• In the EE mode of DV input in the 32 kHz
audio mode.
• In the 48kHz audio mode or during normal
recording, it outputs to CH1/2 channel (the
OUTPUT switch listed in the above table
shows the setting of CH1/2).
• When MIX is selected, the PHONES termi-
nal outputs stereo sound.
●
Digital output
IEEE1394-compliant digital signals are output
from the DV IN/OUT terminal.
Input signal
●
Analog signal
CH 1/3 AUDIO IN terminal. (RCA
2)
There are analog input terminals for 2 chan-
nels. Recording cannot be performed to 4 chan-
nels at the same time. Sound from each termi-
nal is usually recorded to CH1 and CH2.
To record to CH 3 and CH 4, set AUDIO MODE
of the AUDIO Menu screen to 32 k and record
it in the audio-dubbing mode. (
☞
Page 44)
●
Microphone input terminal
This terminal is for connecting to a monaural
microphone. The same sound is recorded on
the 2 channels.
Memo
●
To record sound on the AUDIO IN terminal
and MIC terminal, set the INPUT SELECT
switch on the front panel to “LINE” or “Y/C
(CPN)”.
●
If the AUDIO IN terminal and MIC terminal
are used at the same time, the MIC terminal
precedes.
●
Digital input
IEEE1394-compliant digital signals are input
into the DV IN/OUT terminal.
• To enable audio input into this terminal, set
the INPUT SELECT switch to DV.
• The AUDIO MODE (48 K or 32 K) will be one
of input signals.
• During digital signal input, the recording level
cannot be adjusted.
Memo
●
An input/output board (sold separately) of the
XLR connector can be installed in the optional
slot.
SA-X61U AUDIO XLR IN board
SA-X62U AUDIO XLR OUT board
These boards cannot be installed at the same
time.
●
For BR-DV600 player, when the mode is
changed from STILL to PLAY, sound will be
muted for a while shortly after the audio out-
put. Thereafter, it will resume as per normal.
(This does not occur with BR-DV600A.)
AUDIO switch
MONITOR OUT/
PHONES terminal
MONITOR
L
MIX
R
OUTPUT
CH1/2
MIX
CH3/4
CH1/2
MIX
CH3/4
CH1/2
MIX
CH3/4
CH1
CH1/3
CH3
CH1/2
CH1/2/3/4
CH3/4
CH2
CH2/4
CH4
DV6000E_28-051_Eng.p65e
06/03/03, 3:31 PM
31