No. 51955
AV42PD20ES
33
Item
Measuring
instrument
Test point
Ad justment part
Description
Checking
of
MAIN COLOUR
DECODER VCO
Signal
generator
Remote
control unit
9. VCO
1. Input a PAL half colour bar signal (75% white) from the EXT
terminal.
2. Select 2. V/C from the SERVICE MENU.
1. Select 9. VCO adjustment with the FUNCTION
▲
/
▼
key.
4. Press the MENU (OK) key then automatically optimized.
Checking
of
PIP COLOUR
DECODER VCO
Signal
generator
Remote
control unit
7. PIP
1. Select 7. PIP from the SERVICE MENU.
2. Receiver a PAL half colour bar (75% white) signal for the
SUB-PICTURE (Right-Side picture)
3. Select 1. PIP VOC ADJ. with the FUNCTION
▲
/
▼
key.
4. Press the MENU (OK) key then automatically optimized.
MAIN
PICTURE
SUB-
PICTURE