10
(3) PIXEL FAULT SPECIFICATION
Screen display
Criteria for number of faulted cell
Criteria for number of
consecutive faulted cell
Bright fault
All blac k screen
A zone:
2
or less than
2
in each colour
B zone:
3
or less than
3
in each colour
2 or Les s than 2
consecutively
Red level 100% on entire sc reen
Green lev el 100% on entire screen
Dark fault
Blue level 100% on entire screen
A zone:
3
or less than
3
in each colour
B zone:
8
or less than
8
in each colour
2 or Les s than 2
consecutively
(Note)
A-zone : Center portion
(area enc losed by 1/4 vertically from the top and bottom and 1/4 horiz ontally from the right and left s ides.)
B-zone : Other area
(Note)
The consecutive pixel fault that are diagonally or intensively generated shall be interpreted as follows :
B zone
A zone
52.9cm
(1/4V)
(1/4H)
(1/4H)
(1/4V)
→
→
→
→
cons ecutive 3
→
→
→
→
cons ecutive 3
→
→
→
→
cons ecutive 4