No. 51955
AV42PD20ES
30
Item
Measuring
instrument
Test point
Ad justment part
Description
[Method of adjustment without measuring instrument]
< PAL COLOUR >
1. Receive PAL broadcast.
2. Select 2.V/C from the SERVICE MENU.
3. Select 6.COLOUR with the FUNCTION
▲
/
▼
key.
4. Set the initial s etting value for PAL COLOUR with the
FUNCTION / key.
5. If the colour is not the best with the initial set value, make fine
adjustment until you get the best colour.
6. Press the MENU (OK) key and memorize the set value.
< SECAM COLOUR >
1. Receive a SECAM broadc ast.
2. Make fine adjustment of SECAM COLOUR in the same manner
as for above.
< NT SC 3.58 COLOUR >
1. Input a NTSC 3.58MHz COMPOSITE VIDEO signal from the
EXT terminal.
2. Make s imilar fine adjus tment of NTSC 3.58 COLOUR in the
same manner as for above.
Ad justment
of SUB
COLOUR
Ⅰ
Ⅰ
Ⅰ
Ⅰ
Remote
control unit
6.COLOUR
< NT SC 4.43 COLOUR >
1. Input a NTSC 4.43MHz COMPOSITE VIDEO s ignal from the
EXT terminal.
2. Make similar fine adjustment of 4.43 COLOUR in the same
manner as for above.
MENU
( OK ) key
FUNCTION
▲
▲
▲
▲
/
▼
▼
▼
▼
& /
key
(
INFORMATION
) key
i
NUMBERS
key
SUB POWER
key