(No.YA097)1-63
SUB COLOR /
SUB TINT /
B-Y GAIN
adjustment (1)
Signal
generator
Remote
control unit
TP-R
[R CRT
SOCKET PWB]
TP-B
[B CRT
SOCKET PWB]
TP-E (GND)
[1.PICTURE/SOUND]
S01 : COLOR
S02 : TINT
S07 : B-Y
[ Method of adjustment without measuring instrument ]
(1) Receive NTSC color bar signal (include 75% white).
(2) Select STANDARD mode with [VIDEO STATUS]
key.
(3) Select 1.PICTURE/SOUND from SERVICE MENU.
(4) Select < S01 > (COLOR) and < S02 > (TINT).
(5) Set the initial setting value.
(6) If the color or tint is not the best with the initial setting
values, make fine adjustment until you get the best
color or the best tint.
(7) Select < S07 > (B-Y).
(8) Set the initial setting value.
(9) If the color bar is not clearly with the initial setting
value, make fine adjustment until you get the clearly
color bar.
(10) Press [MUTING] key to memorize the set value.
(11) Select THEATER mode with [VIDEO STATUS] key.
(12) Repeat steps 3 ~ 10 above.
(13) Input 480i component color bar signal from
COMPONENT VIDEO terminal.
(14) Repeat steps 2 ~ 12 above.
(15) Input 480p component color bar signal from
COMPONENT VIDEO terminal.
(16) Repeat steps 2 ~ 12 above.
(17) Input 1080i component color bar signal from
COMPONENT VIDEO terminal.
(18) Repeat steps 2 ~ 12 above.
Item
Measuring
instrument
Test point
Adjustment part
Description
Signal
Item
S01
STANDARD
THEATER
NTSC
480i
480p
Initial setting value
096
083
STANDARD
THEATER
075
STANDARD
THEATER
076
085
079
720p / 1080i
STANDARD
THEATER
071
074
S02
060
050
068
066
062
059
065
065
S07
017
027
024
018
012
013
020
019
Содержание AV-48WP55/H
Страница 68: ...1 68 No YA097 ...