(No.YA097)1-51
4.7
ADJUSTMENT PROCEDURE
4.7.1 CHECK ITEMS
4.7.2 HORIZONTAL FREQUENCY ADJUSTMENT
Item
Measuring
instrument
Test point
Adjustment part
Description
X-RAY
PROTECTOR
check
Resistor
[6.8k
Ω
1/4W ±34
Ω
]
S1 connector
2 pin : X-Ray2
3 pin : X-Ray1
[DEF/
CONVEGENCE
OUT PWB]
(1) Receive NTSC whole black signal.
(2) Connect resistor 6.8k
Ω
(1/4W, ±34
Ω
) between 2 pin
& 3 pin of the S1 connector.
(3) Confirm that the X-RAY protector functions operated.
HIGH VOLTAGE
check
Signal
generator
HV voltmeter
CRT Anode
(1) Receive NTSC whole black signal.
(2) Connect the HV voltmeter between CRT anode and
GND.
(3) Check the high voltage DC 31.0kV (+1.0kV / -1.3kv).
Item
Measuring
instrument
Test point
Adjustment part
Description
H. FREQUENCY
adjustment
Signal
generator
Remote
control unit
[1.PICTURE/SOUND]
D15 : H. FREQ.
D18 : DEF. RST
(1) Receive NTSC crosshatch signal.
(2) Select FULL mode with [ASPECT] key.
(3) Select 1. PICTURE/SOUND from SERVICE MENU.
(4) Select < D18 > (DEF. RST) and change the data 0
to 1 (free run).
(5) While observing the screen, adjust the < D15 >
(H. FREQ) so that an optimum horizontal
synchronization is obtained. (see figure)
(6) Press [MUTING] key to memorize the set value.
(7) After adjustment, select < D18 > and change the
data 1 to 0.
(8) Press [MUTING] key to memorize the set value.
T502
FBT
CN008
X-RAY
RESISTOR
6.8K 34 1/4W
SERVICE CONNECTOR
TP-E
R561
R563
D561
D562
C311
R562
FR311
D311
B1
TP-91
R565
X-RAY2
1 2 3 4 5
X-RAY1
NC
TP-91B
139.5V
TP-E
( )
2
3
1
S1
CONNECTOR
S1
5
4
3
2
1
Optimum synchronization
(Horizontal frequency
optimal condition)
Unoptimum synchronization
(Horizontal frequency difference)
Содержание AV-48WP55/H