You ground the SSR120 by connecting a grounding cable to earth ground and then attaching the grounding
cable to the chassis grounding point located on the rear of the appliance.
To ground the appliance:
1. Wrap and fasten one end of the ESD grounding strap around your wrist and connect the other end to
a site ESD point. For more details, see Prevention of Electrostatic Discharge Damage.
2. Ensure that all grounding surfaces are clean and brought to a bright finish before grounding connections
are made.
3. Connect the grounding cable to a proper earth ground, such as the rack in which the appliance is
mounted.
4. Using a Phillips screwdriver remove the screw from the grounding point on the rear of the chassis.
5. Place the grounding cable lug attached to the grounding cable over the grounding point.
6. Secure the grounding cable lug to the grounding point with the screw.
Figure 14: Connecting the Grounding Cable to the SSR120
7. Dress the grounding cable and verify that it does not touch or block access to the appliance components
and that it does not drape where people could trip on it.
NOTE:
The appliance should be permanently connected to ground during operation.
36
Содержание SSR120
Страница 1: ...SSR120 Hardware Guide Published 2022 01 17 ...
Страница 7: ...1 CHAPTER Overview SSR120 Appliance Overview 8 SSR120 Chassis 10 LTE Support on SSR120 Appliances 15 ...
Страница 48: ...3 Verify that all four Device interfaces are up 48 ...
Страница 54: ...Lithium Battery Declaration 87 ...
Страница 56: ...56 ...
Страница 60: ...Restricted Access Warning 60 ...
Страница 72: ...Unterminated Fiber Optic Cable Warning 72 ...
Страница 78: ...Jewelry Removal Warning 78 ...
Страница 81: ...Operating Temperature Warning 81 ...