Table 41: Component LEDs on the SRX240 Services Gateway
(continued)
Possible Causes and
Corrective Actions
Meaning
State
LED
Normal condition. No action
is required.
Output is normal.
Green
DC Power
System Feeds
LEDs
Input is connected but has
failed because the power
supply fuse has failed or the
input voltage is low.
•
Verify that the source
circuit breaker has the
proper current rating.
Each power supply must
be connected to a
separate source circuit
breaker.
•
Check whether the DC
power cables from the
power source to the
device are not damaged.
If the insulation is
cracked or broken,
immediately replace the
cable.
•
Contact the Juniper
Networks Technical
Assistance Center
(JTAC). See
Networks Technical
Assistance Center” on
page 118
The port has detected a
failure.
Red (blinking)
Both inputs are normal but
no output because of
output side failure or open
connection.
•
Connect the power
supply feeds to a
different power source
with a new power cables.
•
Contact the Juniper
Networks Technical
Assistance Center
(JTAC). See
Networks Technical
Assistance Center” on
page 118
The port has detected a
failure.
Red (steady)
Normal condition if the
services gateway is
switched off. No action is
required.
No output
Off
Copyright © 2015, Juniper Networks, Inc.
110
SRX240 Services Gateway Hardware Guide
Содержание SRX240 Series
Страница 1: ...SRX240 Services Gateway Hardware Guide Modified 2015 06 08 Copyright 2015 Juniper Networks Inc ...
Страница 8: ...Copyright 2015 Juniper Networks Inc viii SRX240 Services Gateway Hardware Guide ...
Страница 18: ...Copyright 2015 Juniper Networks Inc xviii SRX240 Services Gateway Hardware Guide ...
Страница 20: ...Copyright 2015 Juniper Networks Inc 2 SRX240 Services Gateway Hardware Guide ...
Страница 26: ...Copyright 2015 Juniper Networks Inc 8 SRX240 Services Gateway Hardware Guide ...
Страница 30: ...Copyright 2015 Juniper Networks Inc 12 SRX240 Services Gateway Hardware Guide ...
Страница 46: ...Copyright 2015 Juniper Networks Inc 28 SRX240 Services Gateway Hardware Guide ...
Страница 58: ...Copyright 2015 Juniper Networks Inc 40 SRX240 Services Gateway Hardware Guide ...
Страница 62: ...Copyright 2015 Juniper Networks Inc 44 SRX240 Services Gateway Hardware Guide ...
Страница 64: ...Copyright 2015 Juniper Networks Inc 46 SRX240 Services Gateway Hardware Guide ...
Страница 72: ...To install the device in a rack Copyright 2015 Juniper Networks Inc 54 SRX240 Services Gateway Hardware Guide ...
Страница 76: ...Copyright 2015 Juniper Networks Inc 58 SRX240 Services Gateway Hardware Guide ...
Страница 80: ...Copyright 2015 Juniper Networks Inc 62 SRX240 Services Gateway Hardware Guide ...
Страница 86: ...Copyright 2015 Juniper Networks Inc 68 SRX240 Services Gateway Hardware Guide ...
Страница 96: ...Copyright 2015 Juniper Networks Inc 78 SRX240 Services Gateway Hardware Guide ...
Страница 120: ...Copyright 2015 Juniper Networks Inc 102 SRX240 Services Gateway Hardware Guide ...
Страница 122: ...Copyright 2015 Juniper Networks Inc 104 SRX240 Services Gateway Hardware Guide ...
Страница 138: ...Copyright 2015 Juniper Networks Inc 120 SRX240 Services Gateway Hardware Guide ...
Страница 142: ...Copyright 2015 Juniper Networks Inc 124 SRX240 Services Gateway Hardware Guide ...
Страница 148: ...Copyright 2015 Juniper Networks Inc 130 SRX240 Services Gateway Hardware Guide ...
Страница 150: ...Copyright 2015 Juniper Networks Inc 132 SRX240 Services Gateway Hardware Guide ...
Страница 158: ...Copyright 2015 Juniper Networks Inc 140 SRX240 Services Gateway Hardware Guide ...
Страница 186: ...Copyright 2015 Juniper Networks Inc 168 SRX240 Services Gateway Hardware Guide ...
Страница 192: ...Copyright 2015 Juniper Networks Inc 174 SRX240 Services Gateway Hardware Guide ...
Страница 193: ...PART 7 Index Index on page 177 175 Copyright 2015 Juniper Networks Inc ...
Страница 194: ...Copyright 2015 Juniper Networks Inc 176 SRX240 Services Gateway Hardware Guide ...
Страница 198: ...Copyright 2015 Juniper Networks Inc 180 SRX240 Services Gateway Hardware Guide ...