Environmental Requirements and Specifications for EX Series Switches
The switch must be installed in a rack or cabinet housed in a dry, clean, well-ventilated,
and temperature-controlled environment.
Ensure that these environmental guidelines are followed:
•
The site must be as dust-free as possible, because dust can clog air intake vents and
filters, reducing the efficiency of the switch cooling system.
•
Maintain ambient airflow for normal switch operation. If the airflow is blocked or
restricted, or if the intake air is too warm, the switch might overheat, leading to the
switch temperature monitor shutting down the switch to protect the hardware
components.
provides the required environmental conditions for normal switch
operation.
Table 16: EX Series Switch Environmental Tolerances
Environment Tolerance
Switch or
device
Seismic
Temperature
Relative Humidity
Altitude
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
at altitudes up to 5,000 ft
(1,524 m).
For information about extended
temperature SFP transceivers
supported on EX2200 switches,
see
Supported on EX2200
Switches” on page 52
.
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
5,000 feet (1524
meters)
EX2200-C
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in
the temperature range 32° F
(0° C) through 113° F (45° C)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX2200
(except
EX2200-C
switches)
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
5,000 feet
(1524 meters)
EX2300-C
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation ensured in
the temperature range 32° F
(0° C) through 113° F (45° C)
Normal operation ensured in
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
13,000 feet
(3962 meters) at 104°
F (40° C) as per
GR-63
EX2300
(except
EX2300-C
switches)
43
Copyright © 2018, Juniper Networks, Inc.
Chapter 2: Site Planning, Preparation, and Specifications
Содержание EX2200 Series
Страница 1: ...EX2200 and EX2200 C Switches Hardware Guide Modified 2018 12 18 Copyright 2018 Juniper Networks Inc...
Страница 8: ...Copyright 2018 Juniper Networks Inc viii EX2200 and EX2200 C Switches Hardware Guide...
Страница 12: ...Copyright 2018 Juniper Networks Inc xii EX2200 and EX2200 C Switches Hardware Guide...
Страница 20: ...Copyright 2018 Juniper Networks Inc xx EX2200 and EX2200 C Switches Hardware Guide...
Страница 40: ...Copyright 2018 Juniper Networks Inc 40 EX2200 and EX2200 C Switches Hardware Guide...
Страница 66: ...Copyright 2018 Juniper Networks Inc 66 EX2200 and EX2200 C Switches Hardware Guide...
Страница 150: ...Copyright 2018 Juniper Networks Inc 150 EX2200 and EX2200 C Switches Hardware Guide...
Страница 168: ...Copyright 2018 Juniper Networks Inc 168 EX2200 and EX2200 C Switches Hardware Guide...
Страница 174: ...Copyright 2018 Juniper Networks Inc 174 EX2200 and EX2200 C Switches Hardware Guide...
Страница 214: ...Copyright 2018 Juniper Networks Inc 214 EX2200 and EX2200 C Switches Hardware Guide...