digital audio
modular
processing system
C8000
64ch BNC MADI & AoIP I/O
C8315
3/20
installation
Initial set up
ADDRESS:
This
rotary encoder
sets the
CAN ID
of the
C8315
. The switch positions are
hexadecimal numbers (0x0 to 0xF). The CAN address also defines the
location of the module icon within the GUI overview of rows three to six.
SW2:
#1 BUS-EN
ON
= The output configuration will be taken from the
NV
(non volatile)
memory
after power up.
OFF
= will set all bus outputs to Tri-State-Mode (inactive).
Now you may use the frame controller to configure the board.
This configuration will automatically be stored into the
NV memory
To enable the configuration for the next power up you must
pull out
the module and set
BUS-EN=ON
again.
Important note!
Since this type of module has an electronic output routing facility, great care must be
taken when installing or exchanging a module when such frame has components which are On Air!
If an unknown output bus configuration is stored, it can cause a conflict with other modules in the frame.
If you are not sure about the output bus configuration you must turn
BUS-EN=OFF
before inserting such a
module into a system that is On Air. If all settings are done remotely and the unit fits into the bus
assignment scheme of that frame, you must remove it and place the switch back into position
BUS-EN=ON
to activate this setting for the
next
power up(s).
BDS
B
O
O
T
ADDRESS
SW2
BUS-EN
H-CAN
BOOT
ID +16
MASTER
DANTE
1 : 1
POWER:
OK /
FAIL
INIT
O
N
D
IP
1
2 3
4
5
6 7
8