digital audio
modular
processing system
C8000
64ch BNC MADI & AoIP I/O
C8315
4/20
#2 H-CAN
OFF
= CAN bus speed 256kBit/s
ON
= CAN bus speed 1Mbit/s
Important Note!
For a limited number of modules like the
C8315
it is possible to communicate with a
CAN bus speed of 1MBit/s. This provides more bandwidth to move measuring data from the module via
the frame controller to the
J*AM
based loudness logger. Be sure that all modules within a frame are
operating with the same CAN bus speed.
#3 BOOT
OFF
= Internal use and
must
be set to
OFF
.
#4
ID +16
OFF
=
CAN
bus address range is standard (counting from 0x0 to 0xF)
see rotary encoder settings above.
ON
=
CAN
bus address range is extended by
+16
(counting from 0x10 to 0x1F).
#5 MASTER
OFF
= Sync is taken from the
c8k
frame
ON
= The
C8315
will be
sync master
of the frame (or an C8934 island).
Sync source is defined by SW2 #6
#6 DANTE
OFF
=
MADI
is sync reference.
ON
=
DANTE
is sync reference.
#7 1 : 1
OFF
= Remote controlled operation by
C8702
frame controller.
ON
= Stand alone operation.
MADI
and
AS67
interfaces are bridged.
#8
OFF
= Internal use and
must
be set to
OFF
.
INIT
Pressing the
INIT
button during power up will initialize the module
parameters to factory default values.