Dimming light with dimming insert 

The light can be dimmed using a 2-wire extension. The light remains at the dimmed value until 
the run-on time has elapsed. 

Press 2-wire insert at top or bottom until the desired brightness is reached. 

An installation button cannot be used for dimming. 

Saving a switch-on brightness with dimming insert 

A 2-wire extension can be used to save any desired switch-on brightness. In the state as 
supplied the switch-on brightness is set to maximum. 
The saved switch-on brightness is retained in the event of a power failure. 

Set the required brightness. 

Press 2-wire extension for longer than 3 seconds over entire surface. 
Switch-on brightness is saved. For confirmation the lighting switches off briefly and then on 
again to the saved switch-on brightness. 

5 Information for electrically skilled persons 

5.1 Fitting and electrical connection 

DANGER! 
Electrical shock when live parts are touched. 
Electrical shocks can be fatal. 
Before carrying out work on the device or load, disengage all the 
corresponding circuit breakers. Cover up live parts in the working environment. 

Selecting the installation location 

Figure 2: Sensor window and detection area 

The motion detector has a detection area of 360° (figure 2). The diameter of the detection area 
depends on the installation height and the direction of motions of persons in the detection area 
(figure 3). At an installation height of 3 m the maximum diameter on the floor is approx. 12 to 20 
m. 

3/8 

82563813 
J:0082563813 

17.11.2011 

Light Management  

Ceiling automatic switch 

Содержание DAW 360 WW

Страница 1: ...breakers that supply dangerous voltage to the device or load Danger of electric shock Device is not suitable for disconnection from supply voltage The load is not electrically isolated from the mains even when the device is switched off Do not press on the sensor window Device can be damaged The device is not suitable for use as a burglar alarm or other alarm These instructions are an integral par...

Страница 2: ...brightness and then switched off The time from the start of dimming to switching off is always approx 30 s If a motion is detected during the dimming phase the motion detector switches the lighting to the stored switch on brightness again Behaviour in case of a mains failure Less than 0 2 seconds the old switching position is restored after mains return 0 2 seconds to approx 2 seconds when the pow...

Страница 3: ...ness is saved For confirmation the lighting switches off briefly and then on again to the saved switch on brightness 5 Information for electrically skilled persons 5 1 Fitting and electrical connection DANGER Electrical shock when live parts are touched Electrical shocks can be fatal Before carrying out work on the device or load disengage all the corresponding circuit breakers Cover up live parts...

Страница 4: ...ightness sensor is on the side away from the windows This reduces the effects of scattered light o Connect flush mounted insert properly and mount in accordance with the orientation of the motion detector see instructions for flush mounted insert i Use a surface mounted housing for surface installation i Use a wind tight connector socket for cavity wall mounting o Attach the motion detector cover ...

Страница 5: ...cted switch on will take place again after a lockout time of approx 3 seconds In test operation the motion detector operates independently of the brightness o Leave the detection area and observe the switching behaviour If the motion detector switches on then sources of interference must be hidden see Limiting the detection area o Measure the detection area If the detection area is too large limit...

Страница 6: ...th of the run on time Each detected movement restarts the run on time again The run on time is set in a range from approx 10 seconds to 30 minutes o Pull off decor ring o Turn the time adjuster 4 to the required position figure 4 o Attach decor ring Setting test mode short time operation The motion detector can be set to short time mode e g to use it to control acoustic signal generators If motion...

Страница 7: ... operations reduce the sensitivity o Attach decor ring 6 Appendix 6 1 Technical data Ambient temperature 5 35 C Protection rating IP 20 Brightness setting approx 0 80 lx and day operation run on time approx 10 s 30 min Lockout time approx 2 s Follow up time test approx 1 s Lockout time test approx 3 s Size of detection area at an installation height of 3 m cross walking range Ø approx 20 m walk to...

Страница 8: ... free with a description of the defect to our central customer service office ALBRECHT JUNG GMBH CO KG Service Center Kupferstr 17 19 D 44532 Lünen Service Line 49 0 23 55 80 65 51 Telefax 49 0 23 55 80 61 89 kundencenter jung de General equipment Service Line 49 0 23 55 80 65 55 Telefax 49 0 23 55 80 62 55 kundencenter jung de KNX equipment Service Line 49 0 23 55 80 65 56 Telefax 49 0 23 55 80 6...

Отзывы: