Limiting the detection area
Figure 5: Push-on cover
The push-on cover can be used to limit the detection area, e.g. in order to mask out
interference sources.
Cover size
Detection area on the floor
Complete push-on cover
Ø approx 4.5 m
Area I cut out
Ø approx 7.5 m
Areas I + II cut out
Ø approx 12 m
without push-on cover
Ø approx. 20m
All data are applicable for an installation height of 3 m and a direction of motion transverse to
the motion detector.
o
Pull off push-on cover
o
Using scissors, cut out push-on cover along the marked lines as required.
o
Push on push-on cover
Set follow-up time
Then the lighting remains switched on for the length of the run-on time. Each detected
movement restarts the run-on time again. The run-on time is set in a range from
approx. 10 seconds to 30 minutes.
o
Pull off decor ring.
o
Turn the
time
adjuster (4) to the required position (figure 4).
o
Attach decor ring.
Setting test mode / short-time operation
The motion detector can be set to short-time mode, e.g. to use it to control acoustic signal
generators. If motion is detected, the motion detector switches on, depending on the brightness,
for 1 second. If motions are still detected, switch-on will take place again after a lockout time of
approx. 3 seconds.
o
Pull off decor ring.
o
Set
time
adjuster (4) to
test
(figure 4).
o
Turn
sens
adjuster (3) slightly in the
min
direction, because at maximum sensitivity
unwanted switching may occur.
6/8
82563813
J:0082563813
17.11.2011
Light Management
Ceiling automatic switch