Pressure vessel

Pressure tested at:       4­25 liter: 

 

 

 

 

 

 

 

40­50 liter:

Directions for use
Application 

Receiver for compressed air.

Receiver specifications  See name plate.
Installation 

Tubes, etc. must be made of  

 

 

 

suitable materials.

Placement 

Observe the working temperature    

 

 

of the receiver.

 

 

Ensure that sufficient room for  

 

 

 

inspection/maintenance is  

 

 

 

available in a horizontal position.

 

 

The receiver must be kept in a  

 

 

 

horizontal position.

Corrosion protection 

The surface treatment must be  

 

 

 

maintained as required.

 

 

Internal inspection at least every    

 

 

5 years.

 

 

Drain moisture at least once a week.

Alternation/repair 

No welding must be made on  

 

 

 

pressurized parts.

Safety valve 

Ensures that PS will not be exceeded.

 

 

Never adjust to a higher pressure    

 

 

than PS.

 

 

The capacity of the valve must be    

 

 

calculated in accordance   

 

 

with the volume of air supplied by    

 

 

the compressor.

 

 

(PS = Maximum working pressure    

 

 

of the receiver)

Declaration of Conformity

NOTE: The declaration of conformity is only valid for units 
operating at 20 V/50 Hz, x400 V/50 Hz, 12 V DC or 24 V DC.

The manufacturer, JUN­AIR International A/S, declares that the 
products mentioned in this manual are in conformity with:
•  87/404/EEC ­ 90/488/EEC ­ 9/68/EEC Council Directive  
 

relating to Simple Pressure Vessels

•  89/92/EEC ­ 91/68/EEC ­ 9/44/EEC ­ 9/68/EEC  

 

 

Council Directive of Safety of Machinery               

•  89/6/EEC Council Directive of Electric Magnetic  

 

 

Compatibility 

•  7/2/EEC Low­voltage Directive

Flemming Petersen
Quality Manager

24 bar

18.3 bar

 

c)  Failure in non­return valve which is creating a flow 

restriction.

 

d)  Check the piston gaskets. Replace, if necessary.

 

e)  Desiccant has been contaminated and/or filter elements 

have been   clogged (this only applies to model „D“). 
Replace. See "Adsorption Dryer Manual".

4.  Loud noise from compressor:
 

a)  Dirt or failure in non­return valve. Clean or replace.

 

b)  Defective fan (this only applies to model „P“).

5.  Compressor gets very hot:
 

a)  Leaks. See point b.

 

b)  Intake filter clogged. See point a.

 

c)  Too high ambient temperature. Do not enclose unit in a 

cupboard unless adequately ventilated. The compressor 
should be placed in coolest possible place.

 

d)  The cooling fan at the top of the cabinet does not run 

(this only applies to model „P“). Check pipes and fuses.

 

e)  Overloaded. Ensure compressor is correct model for 

work load.

6.  Compressor starts when no air is being tapped:
 

a)  Leaks. See point b.

7.  Compressor starts and stops more frequently than 

usually:

 

a)  Large amount of condensate in air receiver (on units 

without dryer). On units with dryer condensate may be 
found if dryer is defective (this only applies to model 
„D“).

 

b)  Leaks. See point b.

8.  Compressor does not switch on against pressure or 

does not switch off at max. pressure:

 

a)  Defective pressure switch. Replace.

Operating manual

GB

Содержание 1000 motor

Страница 1: ...ng manual Bruksanvisning Compressor Model 1000 motor 1000 25B 1000 25BD2 2000 motor 2000 40B 2000 40BD2 2000 40P 2000 40PD2 4000 40B 4000 40BD3 4000 150B 4000 150BD3 4000 150P 4000 150PD3 6000 150B 80...

Страница 2: ......

Страница 3: ...Operating manual 4 Bruksanvisning 7 10 Technical data 14 Tekniska data 14 14 Spare parts 18 Reservdelslista 18 18 Pictures illustrations 35 Bilder illustrationer 35 35 GB RU SE...

Страница 4: ...gs for ventila tion are available on top and bottom minimum 500 cm 77 5 in each If the compressor is placed under a table a minimum of 20 cm 7 9 in free height must be available above the compressor o...

Страница 5: ...the filter element needs replacement the indicator turns red instead of green Under normal conditions the filter element must be replaced after approx 4000 working hours If the environment is very con...

Страница 6: ...44 EEC 93 68 EEC Council Directive of Safety of Machinery 89 336 EEC Council Directive of Electric Magnetic Compatibility 73 23 EEC Low voltage Directive Flemming Petersen Quality Manager 24 bar 18 3...

Страница 7: ...p om det ej finns riktiga ventilations ppningar i toppen och botten min 500 cm var Om kompressorn placeras under t ex en bordsskiva ska det vara en fri h jd p min 20 cm eller kan det g ras en ppning p...

Страница 8: ...ckfall i f r och efterfiltret p torkaren r detta f rsett med en pop up indikator som skiftar fr n gr n till r d n r filterelementet skall bytas Under normala f rh llanden skall filtret bytas efter ca...

Страница 9: ...8 EEC Council Directive av Maskindirektivet 89 336 EEC Council Directive av EMC direktivet Electric Magnetic Compatibility 73 23 L gsp nningsdirektivet Flemming Petersen Quality Manager 24 bar 18 3 ba...

Страница 10: ...AIR International A S 20 EMS 89 336 EEC 03 1989 JUN AIR 2 5 JUN AIR s Conditions for Sale and Delivery JUN AIR International A S JUN AIR 1 2 20 2 77 5 2 20 7 9 30 11 8 3 1 4 1 4 BSP 2 5 BD PD 3 6 230...

Страница 11: ...11 10 4 A B 6 B A 6 8 90 120 psi 50 15 8 120 psi 15 14 2 30 psi 32 89 F BD PD 2000 RU...

Страница 12: ...12 2000 1 2 5 3 6 1 2 4 3 2 4 1 0 2 3 8 120 psi 1 a b c d 2 a 3 b c 1 d e f D 4 a b P 5 a 3b b 3a c d P e 6 a 3b 7 a D b 3b 8 b RU...

Страница 13: ...50 18 3 5 230 V 50 Hz 3x400 V 50 Hz 12 V DC or 24 V DC JUN AIR International A S 87 404 EEC 90 488 EEC 93 68 EEC 89 392 EEC 91 368 EEC 93 44 EEC 93 68 EEC 89 336 EEC 73 23 EEC Flemming Petersen Quali...

Страница 14: ...450 x 260 x 320 Inch 17 5 x 10 2 x 12 4 Noise level 1 m dB a 70 72 72 70 72 Model 1000 25B 1000 25BD2 Tank size liter 25 25 US gallon 6 6 6 6 Weight kg 40 49 lbs 88 108 Dimensions l x w x h mm 450 x 4...

Страница 15: ...150 US gallon 39 6 39 6 39 6 39 6 Weight kg 126 134 167 200 lbs 278 295 368 441 Dimensions l x w x h mm 1280 x 520 x 810 1280 x 570 x 810 1280 x 520 x 830 1510 x 520 x 830 Inch 50 1 x 20 2 x 31 6 50 1...

Страница 16: ...ning Frequency Frekvens Frequency Motor HP Motor HK W Displacement Kapacitet n Max pressure Maximalt arbejdstryck Max current Str mf rbruk Tank size Beh llare Weight Vikt Dimensions l x w x h Dimensio...

Страница 17: ...0 12 0 14 0 50 Hz 60 Hz Model 4000 100 50 1 2 3 0 4 5 6 7 8 bar Ltr min 3 5 3 0 2 0 cu ft min 0 20 40 60 80 100 120 psi 2 5 90 80 70 60 50 Hz 60 Hz Model 1000 190 90 1 2 3 0 4 5 6 7 8 bar Ltr min 7 0...

Страница 18: ...00 Non return valve 5416000 Safety valve 10 bar 145 psi 5420000 Drain cock 1 4 25l 5421100 Drain cock 3 8 40l 50l 5422500 Drain cock 1 4 no tube 5424000 Outlet cock 1 4 5425500 Safety valve T V 10 bar...

Страница 19: ...eturn valve model 12 25 7071000 T piece 1 8 7071200 T piece 1 4 7071300 T piece 1 4 2xinternal external 7071400 T piece Condor 7074500 Coupling 1 4 7156000 Extension piece f cock short 7156100 Extensi...

Страница 20: ...20 Motor spare parts model 1000 0100400 Spare parts...

Страница 21: ...21 Motor spare parts model 2000 0200300 Spare parts...

Страница 22: ...22 0200600 Spare parts model 2000 40B Spare parts...

Страница 23: ...23 Spare parts model 2000 40BD2 0200610 Spare parts...

Страница 24: ...24 0200620 Spare parts model 2000 40P Spare parts...

Страница 25: ...25 0200630 Spare parts model 2000 40PD2 Spare parts...

Страница 26: ...26 Spare parts model 4000 40B 0400200 Spare parts...

Страница 27: ...27 Spare parts model 4000 40BD3 0400210 Spare parts...

Отзывы: