7 Configuration
132
7.14
Counters/integrators
The counters/integrators can be configured as counters, integrators, operating time counters, high-
speed counters, or for determining the total flow (volume):
•
Counters are used to count digital signals.
•
Integrators are used to integrate analog inputs.
•
Operating time counters are used to measure the length of time that digital signals have been active.
•
A high-speed counter can be used to record counter pulses up to 12.5 kHz (via certain optional in-
puts; see technical data).
•
The total flow is determined by integrating the volume flow (see chapter 7.15 "Flow", Page 142).
Stored counter and integrator statuses can be evaluated with the PCA3000 evaluation software on the
PC.
7.14.1
General settings
Device dialog box
Parameter
Parameter
Selection/settings
Description
Synchronization
time
00:00:00
to 23:59:59
Synchronization time for completion and
restart of counters or integrators for
which the "Type" parameter is configured
as "Periodical", "Daily", or "Weekly".
Daily start
00:00:00
to 23:59:59
Start time of counters or integrators
whose "Type" parameters are configured
as "Daily from/to".
Daily end
00:00:00
to 23:59:59
End time of counters or integrators
whose "Type" parameters are configured
as "Daily from/to".
Period
1 min, 2 min,
3 min
, 4 min, 5 min,
10 min, 15 min, 30 min,
1 h, 2 h, 3 h, 4 h, 6 h, 8 h, 12 h
Pulse period of counters or integrators
for which the "Type" parameter is config-
ured as "Periodical".
?
Содержание 706521
Страница 2: ......
Страница 24: ...3 Mounting 24 chapter 11 1 10 Case Page 272...
Страница 36: ...4 Electrical connection 36...
Страница 71: ...71 5 Operation 4 Enter password 5 Confirm process The process can still be aborted here Step Action...
Страница 74: ...5 Operation 74...
Страница 190: ...7 Configuration 190...
Страница 278: ...11 Annex 278...
Страница 279: ......