Product description 

 

24 

 

Technical data 

CORIO CP-201F 

Working temperature range 

°C 

-20 … +200 

Cooling capacity 

°C 

+20 

+10 

-10 

-20 

 

kW 

0.20 

0.17 

0.15 

0.10 

0.02 

 

Refrigerant 

 

R134A 

Dimensions 

Dimensions (W x D x H) 

cm 

44 x 41 x 44 

Usable bath opening 

cm 

13 x 15 

Bath depth 

cm 

15 

Volumes min. … max. 

3.0 … 4.0 

Weight with circulator 

kg 

24.7 

Performance data 

Mains connection  

 

100 V 

50/60 Hz 

115 V 

60 Hz 

230 V 

50/60 Hz 

Current consumption 
(nominal/total) 

4/15 

3/12 

2/16 

Switzerland 

 

 

2/10 

Great Britain 

 

 

2/13 

 

 

 

 

Содержание CORIO CP

Страница 1: ...Heating immersion circulator heating circulator with open bath refrigerated circulator Operating manual 1 950 0900 us V03 12 2021...

Страница 2: ...nt of this operating manual is protected by copyright Information including texts images and other contents may not be reproduced distributed transmitted stored or otherwise used in any form without p...

Страница 3: ...ng and functional elements 15 5 3 1 Key description 16 5 4 Alarm messages 16 5 5 Operating interface 17 5 6 Main menu 18 5 7 Interfaces 19 5 7 1 RS232 interface 19 5 8 Technical data 20 5 8 1 Material...

Страница 4: ...art function 47 8 5 Record data 48 8 5 1 Record measurement data 48 8 5 2 Reading out blackbox data 48 8 6 Adjust pump 49 8 7 Remote control device 49 8 7 1 Remote control device using USB interface 4...

Страница 5: ...ty 58 10 Disposal 61 10 1 Device disposal 61 11 Appendix 62 11 1 Interface commands 62 11 1 1 IN commands 63 11 1 2 OUT commands 64 11 1 3 Status commands 64 11 1 4 Status messages 65 11 2 Alarms and...

Страница 6: ...ent choice JULABO would like to thank you for the trust you have placed in our company and products This operating manual will help you become acquainted with the use of our units Read the operating m...

Страница 7: ...anual can be found on our website www julabo com Use the Search function on the website 2 2 Warnings The manual contains warnings to increase safety when using the device Warnings must always be obser...

Страница 8: ...may be damaged 2 3 Symbols used Various symbols are used throughout this manual to aid reading comprehension This list describes the symbols used Tools needed for the following approach Prerequisite t...

Страница 9: ...edia can be kept constant Only use the device if it is in technically perfect condition and only use it in accordance with its intended use Be aware of safety issues or hazards and comply with the ope...

Страница 10: ...nces and the device The operator must ensure that the device is checked for safety and functionality at regular and usage related intervals The integrity of the safety symbols on the device must be ch...

Страница 11: ...ion These Safety Instructions must be followed to ensure safe operation Vapors may escape during the temperature control application Operate the device in a well ventilated location Depending on the b...

Страница 12: ...efore switching on 4 5 Safety function Technical protective devices provide for safe operation If a safety function is triggered the operator is alerted with a message on the display and an acoustic s...

Страница 13: ...when the bath fluid fill level in the bath tank is too low The device has a two stage warming system to prevent overheating of the heater or dry running of the pump The low liquid level warning is tri...

Страница 14: ...plication Circulator with cooling machine Example CORIO CP 300F for standard temperature applications 5 2 Function description This section describes the function of the device The circulator can be m...

Страница 15: ...1 Mains switch 2 Heating control LED 3 LED display 4 Alarm control LED 5 Cooling control LED 6 Membrane keypad with key panel 7 Service key covered 8 High temperature cut off setting 9 Internal exter...

Страница 16: ...mportant error code descriptions can be found in the appendix If you are unable to rectify a fault contact Technical Service Alarm In the event of an alarm the control LED lights up The temperature co...

Страница 17: ...Product description 17 5 5 Operating interface The device is operated using the four navigation keys The figure shows the menu structure of the user interface Menu structure...

Страница 18: ...de con Set interface parameters Pu Set pump capacity tSEt Set timer SAFE Safety SP Display for high temperature cut off settings SF Display for safety temperature sensor settings tHi Set overtemperatu...

Страница 19: ...evice to a PC RS232 plug RS232 interface pin assignment Pin 2 RxD receive data Pin 7 RTS request to send Pin 3 TxD transmit data Pin 8 CTS clear to send Pin 5 0 V signal GND Pins 1 4 6 and 9 are reser...

Страница 20: ...rnal purposes Class A Use in an industrial electromagnetic environment The device is designed for connection to a separate power transformer or generator Connection to a low voltage line is not permit...

Страница 21: ...stment Pump Volume flow rate at 0 bar l min 8 27 Supply pressure at 0 l bar 0 1 0 7 Maximum viscosity cSt 50 Dimensions Dimensions W x D x H cm 13 2 x 16 0 x 36 2 Immersion depth cm 16 0 Weight kg 2 5...

Страница 22: ...hat the parts are made of This data can be used to check the compatibility of the parts with the bath fluid used Parts that come into contact with the medium Material Motor 1 4301 Pump PPS Heating ele...

Страница 23: ...200 Cooling capacity C 20 10 0 10 20 kW 0 20 0 17 0 15 0 10 0 02 Refrigerant R134A Dimensions Dimensions W x D x H cm 23 x 39 x 65 Usable bath opening cm 13 x 15 Bath depth cm 15 Volumes min max l 3 0...

Страница 24: ...0 02 Refrigerant R134A Dimensions Dimensions W x D x H cm 44 x 41 x 44 Usable bath opening cm 13 x 15 Bath depth cm 15 Volumes min max l 3 0 4 0 Weight with circulator kg 24 7 Performance data Mains c...

Страница 25: ...imensions W x D x H cm 24 x 42 x 66 Usable bath opening cm 13 x 15 Bath depth cm 15 Volumes min max l 3 0 4 0 Weight with circulator kg 28 0 Performance data Mains connection 100 V 50 60 Hz 115 V 60 H...

Страница 26: ...04 Refrigerant R449A R452A Dimensions Dimensions W x D x H cm 33 x 47 x 69 Usable bath opening cm 22 x 15 Bath depth cm 15 Volumes min max l 5 0 7 5 Weight with circulator kg 35 7 Performance data Ma...

Страница 27: ...04 Refrigerant R449A R452A Dimensions Dimensions W x D x H cm 36 x 46 x 74 Usable bath opening cm 22 x 15 Bath depth cm 20 Volumes min max l 8 0 10 0 Weight with circulator kg 38 5 Performance data M...

Страница 28: ...sions Dimensions W x D x H cm 39 x 62 x 75 Usable bath opening cm 26 x 35 Bath depth cm 20 Volumes min max l 21 0 30 0 Weight with circulator kg 52 0 Performance data Mains connection 115 V 60 Hz 200...

Страница 29: ...cm 15 Volumes min max l 5 0 7 5 Weight with circulator kg 51 5 Performance data Mains connection 115 V 60 Hz 200 V 50 60 Hz 230 V 50 60 Hz Current consumption nominal total A 9 16 6 16 6 16 Switzerla...

Страница 30: ...49A Dimensions Dimensions W x D x H cm 45 x 64 x 95 Usable bath opening cm 35 x 41 Bath depth cm 30 Volumes min max l 42 0 56 0 Weight with circulator kg 73 7 Performance data Mains connection 200 V 5...

Страница 31: ...JULABO can damage the water bath Use bath fluids that are recommended by JULABO Before filling check the parts that are in contact with the medium for compatibility with the bath fluid Do not exceed...

Страница 32: ...t the working temperature range and the respective temperature control application Hoses for every area of application can be found on our website Hoses must meet the following requirements Temperatur...

Страница 33: ...ing element may still be hot even after the device has been switched off and may cause burns if touched Allow the device to cool down to room temperature after switching off Wear protective gloves The...

Страница 34: ...operation 1 If possible position the device under an extraction system Depending on the bath fluid gases may be created at high temperatures Recommended minimum distance of 1 m to other devices to pre...

Страница 35: ...the circulator is connected as a bridge mounted circulator or heating circulator The circulator is mounted as a bridge mounted or heating circulator The power cable is ready for use 1 Insert the powe...

Страница 36: ...cable and CAN bus cable are ready for use 1 Connect the network extension cable 1 of the circulator with the cooling machine 2 Connect the CAN plugs of both devices with the CAN bus cable 2 3 Connect...

Страница 37: ...nally connected system If the temperature range and or pressure parameters of an externally connected system do not match those of the device this can result in damage to individual components or even...

Страница 38: ...ween the external system and the temperature control system as backflow protection NOTE Damaged hoses due to kinking Hoses are damaged by kinking and can may leak Lay hoses with large radii Avoid kink...

Страница 39: ...on to the supply and runback position 4 Screw on the pump connections carefully with a maximum of 3 Nm torque 5 Set the flow direction adjustment lever to external circulation The external system is c...

Страница 40: ...ealing plugs 3 Push one barbed fitting through each of the union nuts 4 Mount the barbed fittings with the union nuts on the pump connections 5 Carefully tighten the union nuts with a maximum of 3 Nm...

Страница 41: ...no temperature liquid has been filled yet the low liquid level alarm is displayed Depending on the default setting the high temperature cut off alarm is displayed 2 Press the MENU key 3 Use the arrow...

Страница 42: ...it by refilling or draining Once the working temperature has been reached and the sample inserted the level of bath fluid in the bath tank should cover the heating coil of the heating circulator or th...

Страница 43: ...er on the front control Lever position left external The bath fluid is mainly fed into the external application Lever position right internal The bath fluid is mainly circulated in the internal bath N...

Страница 44: ...nfirm with OK 3 Use the arrow keys to select the menu option cooL and confirm with OK The menu option can only be accessed if the circulator detects a connected refrigeration unit 4 Select the desired...

Страница 45: ...flashing briefly The display switches to tHi 6 Use the arrow keys to switch to the low temperature limit tLo then repeat steps 3 and 4 for the lower temperature limit The temperature warning limits a...

Страница 46: ...ion If a cooling machine is connected the cooling symbol flashes and the cooling machine is shut down Do not switch off the device until the cooling symbol stops flashing and the device is in standby...

Страница 47: ...it switches to a safe operating status in the event of power failure The autostart function is deactivated The display shows OFF The refrigeration aggregate heater and pump motor are disconnected from...

Страница 48: ...s briefly The recording of measurement data is started and indicated on the display by a flashing dot The data is saved onto the USB stick as a txt file Use the arrow keys to select OFF and stop data...

Страница 49: ...device using USB interface The device can be remote controlled via the standard USB B interface The device is switched off The computer has a terminal program installed 1 Connect the circulator USB p...

Страница 50: ...onfirm with OK The display flashes briefly 6 Use the arrow keys to select HAnd handshake and confirm with OK 7 Use the arrow keys to select SOFt software HArd hardware or none none and confirm with OK...

Страница 51: ...connected to a PC via an interface 1 Enter the command status in the terminal program and press Enter The device responds with a status message If an alarm or warning is pending the device sends the r...

Страница 52: ...l reasons there can be a temperature difference in the bath tank between the temperature sensor and a defined more remote point within the bath fluid volume As a result the measured temperature deviat...

Страница 53: ...stabilize for several minutes The more stable the temperature in the bath tank the more precise the adjustment result 7 In menu option Atc use the arrow keys to select the correction point Ct1 and con...

Страница 54: ...sured internally 8 10 Device Reset The function resets the device to the factory settings 1 The device is switched on 1 Press the MENU key 2 Use the arrow keys to select conF and confirm with OK 3 Use...

Страница 55: ...st the high temperature cut off to a temperature that is below the displayed actual value An acoustic signal sounds and the error code E 14 is displayed The high temperature cut off works 2 Then set a...

Страница 56: ...properly disposed of In general the device should be completely emptied before longer shutdowns or when there is a change to the external application CAUTION Risk of burns due to hot bath fluid Bath...

Страница 57: ...surface of the circulator and the bath tank with a damp cloth Some dish detergent may also be used for cleaning If in doubt ask technical service for alternative cleaning mediums The device has now be...

Страница 58: ...pon Seller s receipt of payment in full for the products and subject to Buyer s compliance with the terms of sale and any other agreement with Seller relating to the products Seller warrants to the Bu...

Страница 59: ...acility in Allentown Pennsylvania U S A or at the facility of an authorized representative of Seller which location shall be determined by Seller in its sole discretion provided however that Seller ma...

Страница 60: ...re of the part of Seller to insist on strict compliance with the Warranty Provisions shall no way constitute a waiver of such right No claim or rights arising out of a breach of the Warranty Provision...

Страница 61: ...ect all power cables and if necessary data cables from the circulator and from other connected devices 3 If present disconnect the circulator combination from a connected external application 4 Remove...

Страница 62: ...minal program Interface commands are divided into IN commands and OUT commands String element Symbol Hex Space 20 Carriage return 0D Line feed LF 0A IN commands Retrieve parameters Command structure C...

Страница 63: ...ety sensor in_pv_04 Current setting of the high temperature safety function Setpoints and warning limits System response in_sp_00 Set working temperature in_sp_03 Set high temperature warning limit in...

Страница 64: ...p_07 x Set pump to preset levels 1 5 out_sp_27 xxx Pump capacity in Do not use for reprogramming use out_sp_27 instead Pump stage 4 has an output pressure of approx 450 mbar Device modes Parameter Set...

Страница 65: ...mode remote control operation 03 REMOTE START Device in remote control mode 08 INVALID COMMAND Device did not recognize the last received command 09 COMMAND NOT ALLOWED IN CURRENT OPERATING MODE Last...

Страница 66: ...ture limit or decrease temperature setpoint 04 The measured temperature is below the set low temperature limit Reduce low temperature temperature limit or increase temperature setpoint 05 The cable fo...

Страница 67: ...witch the device on again 70 Devices with incompatible voltage frequency variants connected to each other or devices incorrectly configured Check the permissible operating voltage of the devices and t...

Страница 68: ...ied contact Technical Service 1305 The rotational speed limit for the heating capacity block is not reached Motor defective or viscosity of the bath fluid too high Check pump setting and adjust if nec...

Страница 69: ...the refrigeration unit for damage and replace if necessary Check ambient temperature and reduce if necessary Check CAN bus cable for damage and replace if necessary The specified voltage tolerance of...

Страница 70: ...r codes in ticker text Error code Description Solution CFG error Error during configuration Repeat the process Replace USB stick if this occurs again If the fault has not been remedied contact Technic...

Страница 71: ......

Страница 72: ......

Отзывы: