41
−
Adjustment Procedures
Results of Improper Adjustment
1) Orientation of the lubricating pin
1
When upper looper lubricating pin
1
is set with oil inlet
2
faced upward, lubricating hole
3
is in the lower section as
observed from this side.
2) Setting the lubricating pin
1
Remove the oil reservoir, loosen the setscrew and adjust the
clearance provided between upper looper lubricating pin
1
and upper looper bracket
4
to 0.15 mm using a 0.1 5mm
clearance gauge or the like.
™
If the oil inlet does not face
upward, oil will not be fed
resulting in seizure.
™
I f t h e c l e a r a n c e p r o v i d e d
between the upper looper
lubricating pin and the upper
looper bracket is too small, the
related components will come in
contact with each other.
™
I f t h e c l e a r a n c e p r o v i d e d
between the upper looper
lubricating pin and the upper
looper bracket is too large, oil
will not be fed resulting in
seizure.