−
60
−
Standard Adjustment
(37) Lifting amount of the top feed dog (when the presser lifting lever is operated)
It is the standard that the height from the top surface of the throat plate is 9
±
0.5 mm when presser
lifting lever
5
is pressed at the lowest point of the needle bar and top feed dog
7
goes up to the
highest point. MO-6900J : 10.5
±
0.5 mm
Throat plate
9
±
0.5mm
7
1
2
3
4
5
6
7
Содержание MO-6000S series
Страница 78: ......