86
−
Adjustment Procedures
Results of Improper Adjustment
①
Loosen setscrew
1
and remove thread guide plate
2
.
②
Install air tube
3
to tension controller No. 3
4
and install the
controller almost horizontally to the machine arm with setscrew
5
.
* Refer to Fig. 1 for threading.
Note)
3
,
4
and
5
only are included in tension controller
No. 3 asm. (B50192220B0).
Prepare separately
3
(solenoid valve : PV150209000),
5
(plug : PX500014000) and
6
(solenoid valve
connector asm. : 14204754) described on the next
page.