54
−
X : 0 to
±
50
X : 0 to
±
30
(unit : 1 mm)
0 : Ineffective
1 : Panel reset key
2 : Switch on the machine
head
0 : 161˚ Slow
1 : 149˚
2 : 137˚
3 : 125˚ Fast
0 : Yes
1 : Not defined
2 : Not defined
3 : No
0 : No
1 : Yes
2 : Not adjusted
0 : No
1 : Yes
0 : Wiper sweeps above the
intermediate presser.
1 : Wiper sweeps below the
intermediate presser.
0 : Ineffective
1 : Effective
0 : No correction
1 : Correction is performed.
0 : Normal
1 : Basting
0 : Ineffective
1 : Disk floating
2 : Thread draw-out
0 : Ineffective
1 : Effective
0 : When using the inverting
clamp device
1 : When using the thread
tension controller No. 3
2 : When using both thread
tension controller No. 3 and
inverting clamp device
0 : No
1 : Yes
Travel limit of X-feed or Y-feed is set.
(Setting separated in domains of +X, -X, +Y and -Y is
possible.)
Input of temporary stop switch is selected. (When
selecting panel reset, input of temporary stop is
performed only during sewing operation.)
Feed timing is selected.
When thread is not well-tightened, set 1 or 0 to increase
effect.
Selection of control of simultaneous jump feed with
thread trimming
Effective/ineffective of needle thread breakage
detection function is selected. (Detected at 8 stitches
at sewing start and 3 stitches in midway)
Selection of effective/ineffective of intermediate
presser control
Wiper sweeping position is set.
Whether to perform air pressure detection is selected.
Origin is corrected when using presser of AMS-206.
This function selects the basting mode.
Pattern sewing data is read to "jump feed" and curved
point to "sewing" respectively and the function is
actuated.
Tension disk No. 2 floating function (H type optional),
or thread draw-out function (G and Z types) is selected.
Effective/ineffective of execution of automatic
preparation action after turning ON the power is
selected.
This function controls thread tension controller No. 3
and inverting clamp using the inverting pattern.
Selection of needle bar up-position stop holding mode
Start of feeding is
set by the angle
of main shaft.
C o n t r o l s t a r t s
when "1" or "2" is
set.
Do not use setting
"2".
LK-1942 only
LK-1942 only
Automatic shift of
Y = – 1 2 m m
immediately after
origin retrieval
Optional tension
d i s k f l o a t i n g
s o l e n o i d i s
required at the
time of basting.
(Memory switch
No. 28-1 setting ;
H type only)
In either function,
connect to P59
on MAIN circuit
board.
(Simultaneous
u s e i s n o t
possible.)
+X : 50
–X : 50
+X : 30
–X : 30
2
2
H, G : 3
Z : 0
1
0
0
1
0
0
2
0
1
0
Note)
1.
If the feed timing is set to slow, danger of needle breakage may occur when the cloth is excessively thick. So, be careful.
2.
When ineffective of intermediate presser control is selected, "lifting is fixed". Be sure to remove the intermediate presser since it
comes in contact with needle bar.
In addition, the intermediate presser cam and roller may interfere with each other. Move the intermediate presser cam to the position
where it does not interfere and fix it.
3.
The presser with the inverting clamp is made to special order. For the details, refer to the respective items "Thread tension controller
No. 3 and the inverting clamp device", "How to use the optional thread tension controller No. 3" and "Solenoid valve circuit diagram".
Note
1)
Note
2)
State at the time of delivery
Remarks
Setting range
Function
Display
Note
3)