– 69 –
No.
Item
Setting range
Edit unit
Initial display
Magnet wiper OFF delay time
10 to 500ms
10ms
100ms
Wiper output timing selection at the time of UP
dead point stop
―
―
: UP position
: UP dead point position
Range of move limit in + X direction
−20 to 20mm
1mm
20mm
Range of move limit in -X direction
−20 to 20mm
1mm
-20mm
Range of move limit in +Y direction
−20 to 10mm
1mm
10mm
Range of move limit in -Y direction
−20 to 10mm
1mm
-20mm
In case of LK-
1901/LK-1903,
the initial display
is -10mm.
X/Y jump feed speed is set
100 to 4000pps
10pps
2000pps
X/Y feed forward/backward speed is
set.
100 to 4000pps
10pps
500pps
Selection of effective/ineffective of automatic
preparation motion at the time of turning on the
power
―
―
: Ineffective
: Effective
Selection of effective/ineffective of needle bar stop
holding mode
―
―
: Ineffective
: Effective
Number of pulses of wiper motion
that interlocks the presser
30 to 60
1
45
Содержание LK-1900B/IP-420
Страница 5: ... 1 1 NAME OF EACH SECTION OF THE OPERATION PANEL 1 1 Body Front Right side ...
Страница 12: ... 8 3 2 Sewing screen A B C F N E D O P R Q G J M K H I L ...
Страница 43: ... 39 15 2 Sewing screen A D E F C H R I G L M N Q O P B S V J K T U ...
Страница 56: ... 52 21 2 Sewing screen B A C D S U W T Q R V E O J H I P M N K F X G L ...