23-2-2 Level 2
No.
Item
Setting range
Edit unit
Initial display
Presser switch position of the
standard pedal is set.
10 to 250
1
90
2-motion stroke switch position of
the standard pedal is set.
10 to 250
1
150
Start switch position of the standard
pedal is set.
10 to 250
1
230
Motor-driven work clamp lowering
speed
100 to 4000pps
10pps
4000pps
Motor-driven work clamp lifting
speed
100 to 4000pps
10pps
1500pps
Thread trimmer drive speed
(+ presser rise)
100 to 4000pps
10pps
3000pps
Presser rise motion at sewing end can be set.
―
―
: Normal
: Presser rise prohibited
Thread trimming speed
―
―
: 400sti/min
: 800sti/min
Effective/ineffective selection of thread trimming
jump feed control
―
―
: Ineffective
: Effective
Diameter of needle hole guide at the
time of thread trimming jump feed
control
1.6 to 4.0mm
0.2mm
1.6mm
Selection of prohibition of thread trimmer device
control
―
―
: Normal
: Prohibited
Magnet wiper ON output time
10 to 500ms
10ms
50ms