– 74 –
VIII. ERROR CODE LIST
Error code
Description
How to recover
Place of recovery
E001
Contact of initialization of EEP-ROM of MAIN CON
-
TROL p.c.b.
When data is not written in EEP-ROM or data is broken,
initialization of the data is automatically informed.
Turn OFF the
power.
E007
Main shaft motor-lock
When large needle resistance sewing product is sewn
Turn OFF the
power.
E011
External media not inserted
External media is not inserted.
Possible to re-
cover by reset.
E012
Read error
Data read from external media cannot be performed.
Possible to re-
cover by reset.
Previous screen
E013
Write error
Data write from external media cannot be performed.
Possible to re-
cover by reset.
Previous screen
E014
Write protect
External media is in the write prohibition state
Possible to re-
cover by reset.
Previous screen
E015
Format error
Formatting of external media cannot be performed.
Possible to re-
cover by reset.
Previous screen
E016
External media capacity over
Capacity of external media is short.
Possible to re-
cover by reset.
Previous screen
E017
EEP-ROM capacity over
Capacity of EEP-ROM is short.
Possible to re-
cover by reset.
Previous screen
E018
Type of EER-ROM is different
When the mounted EEP-ROM is different in type.
Turn OFF the
power.
Previous screen
E019
File size over
File size to be read in is too large.
Possible to re-
cover by reset.
Previous screen
E022
File No. error
There is no designated file in the external media.
Possible to re-
cover by reset.
Previous screen
E023
Detection of step-out of presser lifting motor
When step-out of motor is detected at the time when
presser lifting motor passes origin sensor or starts opera-
tion.
Possible to re-
cover by reset.
Standard screen
E024
Pattern data size over
When sewing cannot be performed since total size of
continuous stitching data or size of downloaded data is too
large.
Possible to re-
cover by reset.
Standard screen
1) Checking the error content
Press item select key
❻
to change over the
display between the image display and the expla-
nation display.
1. How to operate the sewing machine in the case an error is displayed
2) Recovering from the error
The sewing machine can be recovered from the
error by carrying out the operation
A
(turning the
power OFF or operating the operation panel) ac-
cording to the error content.
A
A
<Image display>
<Explanation display>
Display
How to recover
Turn OFF the power.
Press the key which is displayed.