– 32 –
(2) Kind of counter
①
Sewing UP counter
Every time the sewing of one shape is performed, the existing value is counted up.
When the existing value is equal to the set value, count-up screen is displayed.
②
Sewing DOWN counter
Every time the sewing of one shape is performed, the existing value is counted down.
When the existing value is reached to "0", count-up screen is displayed.
③
No. of pcs. UP counter
Every time one cycle or one continuous stitching is performed, the existing value is counted up.
When the existing value is equal to the set value, count-up screen is displayed.
④
No. of pcs. DOWN counter
Every time one cycle or one continuous stitching is performed, the existing value is counted
down. When the existing value is reached to "0", count-up screen is displayed.
⑤
Counter not used
(3) Count-up releasing procedure
When count-up condition is reached during
sewing work, the whole count-up screen
E
flashes
on and off. Press RESET key
❸
to reset
the counter, and the mode returns to the sewing
mode. Then the counter starts counting again.
E