2. ERROR COdE LIST (ERROR dISpLAY IN pANEL)
There are the followng error codes n ths devce. These error codes nterlock (or lmt functon) and nform
the problem so that the problem s not enlarged when any problem s dscovered. When you request our
service, please confirm the error codes.
No.
Descrpton of error detected
Cause of occurrence expected
Items to be checked
−
Meda cover open
• Cover of the slot of meda s open.
• Close the cover.
E000 Executon of data ntalza-
ton (Ths s not the error.)
• When the machne head s changed.
• When the ntalzaton operaton s executed
E003 Dsconnecton of synchro-
nzer connector
• When poston detecton sgnal s not nput from
the sewng machne head synchronzer.
• When the synchronzer has broken.
• Belt s loose.
• Machne head s not proper.
• Motor pulley s not proper.
• Check the synchronzer connector (CN33)
for loose connecton and dsconnecton.
• Check whether the synchronzer cord has
broken snce the cord s caught n the
machne head.
• Check the belt tenson.
• Check the settng of the machne head.
• Check the settng of the motor pulley.
E004 Synchronzer lower poston
sensor falure
E005 Synchronzer upper poston
sensor falure
E00 Overload of motor
• When the machne head s locked.
• When sewng extra-heavy materal beyond the
guarantee of the machne head.
• When the motor does not run.
• Motor or drver s broken.
• Check whether the thread has been en-
tangled n the motor pulley.
• Check the motor output connector (4P) for
loose connecton and dsconnecton.
• Check whether there s any holdup when
turnng the motor by hand.
E0 Meda s not nserted.
• Meda s not nserted.
• Turn the power OFF and check the meda.
E02 Read error
• Data of meda cannot be read.
• Turn the power OFF and check the meda.
E03 Wrte error
• Data of meda cannot be wrtten.
• Turn the power OFF and check the meda.
E04 Wrte protect
• Meda s n the state of wrtng prohbton.
• Turn the power OFF and check the meda.
E05 Format error
• Formattng cannot be performed.
• Turn the power OFF and check the meda.
E0 External meda capacty over • Capacty of meda s short.
• Turn the power OFF and check the meda.
E09 Fle sze over
• Fle s too large.
• Turn the power OFF and check the meda.
E032 Fle nterchangeablty error
• There is no interchangeability of file.
• Turn the power OFF and check the meda.
E04 Sewng recorder error
• Ths error number s dsplayed n the event of a
sewng recorder data fault.
• Reset swtch
E044
Date and tme error
• Ths error number s dsplayed n the event of op-
eraton/data fault concernng date or tme of day.
• Reset swtch
E053
Notfcaton of producton
support functon ntalza-
ton (Ths s not an error)
• Ths error number s dsplayed after the execu-
ton of ntalzaton of the producton support
functon or upgradng of the program.
E055
Producton management
error
• Ths error number s dsplayed n the event of
producton management work management
data fault.
• Reset swtch
E05
Work management error
• Ths error number s dsplayed n the event of
data fault.
• Reset swtch
E05
Ptch tme montor error
• Ths error number s dsplayed n the event of
ptch tme montor data fault.
• Reset swtch
E05
Network transmsson
faled
• Ths message s dsplayed n the case data
cannot be sent to the personal computer by
way of the network.
• Check whether the network has any fault.
E0
ID readng faled
• Ths message s dsplayed n the case data n
the ID file is broken.
• Check whether the data has any fault.
E00 Slp of belt
• When the machne head s locked.
• Belt s loose.
• Check whether there s any holdup when
turnng the motor by hand.
• Check the belt tenson.
E0 Dsconnecton of motor
output connector
• Dsconnecton of motor connector
• Check the motor output connector for
loose connecton and dsconnecton.
E02 Overload of motor at the
tme of thread trmmng mo-
ton
• Same as E00
• Same as E00
E204
USB nserton
• Ths message s dsplayed n the case the sew-
ng machne s actvated wth the USB thumb
drve nserted.
• Remove the USB thumb drve.
E205
Warnng of ISS buffer re-
manng amount
• Ths message s dsplayed n the case the buffer
storage for storng the ISS data s almost full.
If the sewng machne s contnuously used wth
the buffer storage full, the stored peces of data
wll be erased from the earlest one.
• Output the data.