– 4 –
!0
9
!1
8
6
7
5) Press swtch
6
or
7
to check the parameter functons (Nos. to 3) and the parameter set values (ds-
played above swtch
9
) related to the ancllary devce "AH0" (MF auto hemmer devce). The type of the
parameter functon and the parameter set value vary dependng on the ancllary devce to be selected.
) To change the parameter set value, press swtch
6
or
7
to dsplay the parameter functon and ts set
value you want to change. Press swtch
8
or
9
to change the parameter set value.
) After the completon of the changng procedure, press swtch
!1
to return the screen to the prevous one.
When you press swtch
!0
, the parameter set value s dscarded and s returned to the value before t s
changed.
5
2
6
3
1
4
■
Thread trimmer setting screen
) Fne adjustment of the thread trmmng acton can be carred out.
2) In the case of the thread trmmer of LU-5* seres, for example, the followng parameters can be adjusted.
: Instantaneous stop tme of thread trmmer
2: Thread trmmer OFF angle
3: Tenson release ON angle
3) Select the parameter you want to adjust wth swtch
1
or
2
. Change the set value of the parameter by
means of swtch
3
or
4
.
4) After the completon of the changng procedure, press swtch
6
to return the screen to the prevous one.
When you press swtch
5
, the parameter set value s dscarded and the parameter set value status s
returned to the state before t s changed.
Содержание IT-100