![JUKI AB-1351 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/juki/ab-1351/ab-1351_instruction-manual_2029580009.webp)
– 4 –
2-3. sewing shape of belt-loops
Work clamp foot for lnear
bartackng
Work clamp foot for zgzag
bartackng
No.1
A
B
A = 4 mm * (-10 to 19)
B = 59 to 99 mm
A = 6 mm * (-9 to 21)
B = 59 to 99 mm
No.2
B
c
A
A = 4 mm * (-10 to 19)
B = 15 to 30 mm
C = 45 to 99 mm
A = 6 mm * (-9 to 21)
B = 15 to 30 mm
C = 45 to 99 mm
No.3
A
c
B
D
A = 4 mm * (-10 to 19)
B = 45 to 109 mm
C = 5 to 11 mm
D = (2) mm
A = 6 mm * (-9 to 21)
B = 45 to 109 mm
C = 5 to 11 mm
D = (2) mm
No.4
c
A
B
D
E
A = 4 mm * (-10 to 19)
B = 30 to 50 mm
C = 5 to 11 mm
D = 5 to 30 mm
E = 6 mm * (-14 to 16)
A = 6 mm * (-9 to 21)
B = 30 to 50 mm
C = 5 to 11 mm
D = 5 to 30 mm
E = 12 mm * (-12 to 22)
No.5
c
A
B
D
F
E
A = 4 mm * (-10 to 19)
B = 30 to 61 mm
C = 5 to 11 mm
D = 2 to 8 mm
E = 2.5 mm * (-2.5 to 7.5)
F = 10 mm * (0 to 20)
A = 6 mm * (-9 to 21)
B = 30 to 61 mm
C = 5 to 11 mm
D = 2 to 8 mm
E = 4 mm * (-1 to 9)
F = 10 mm * (0 to 20)
No.6
A
c
B
D
A = 4 mm * (-16 to 19)
B = 45 to 99 mm
C = 15 to 30 mm
D = 2.5 mm * (-2.5 to 7.5)
A = 6 mm * (-9 to 21)
B = 45 to 99 mm
C = 15 to 30 mm
D = 4 mm * (-1 to 9)
2-2. Electrical specifications
1 Number of patterns that
can be stored n memory
99 patterns can be set.
2 Number of cycles that can
be stored n memory
Number of programs: 20
For each program, as many as 30 belt-loops can be set.
3 Input power source
Sngle-phase 200 – 240 VAC, 50/60Hz
3-phase, 200 - 240 VAC, 50/60 Hz (swtchable to sngle-phase 100 - 120 V)
Supply voltage fluctuation: Rated voltage ± 10 % or less
* Adaptable to 380/400/415 VAC wth the addton of an optonal transformer.
4 Power consumpton
3-phase, 200 V type: 250 VA (nstantaneous maxmum power consumpton: 450 VA)
Sngle-phase, 220 V type: 280 VA (nstantaneous maxmum power consumpton: 670 VA)
* Average power when the machne sews 4000 belt-loops n eght hours under No. 4
sewng mode.