Installation
INFO_NO_HEADER
If the installation is twisted, a func-
tioning of the device is not possible.
1
2
Fig. 3:
Rotary flange fitting
1
Profile flange seal
2
Flow direction arrow
3.3
Installation of the device
CAUTION
If no bypass valve is installed, a
shut-off valve must be installed
upstream of the unit in order to
interrupt the water supply during
installation, maintenance, repair or
malfunction of the device.
Install the device in a vertical posi-
tion (± 5°). Otherwise, water may
escape and cause water damage.
For the installation of the device
in domestic water piping, only use
the supplied built-in rotary flange
(see chapter 3.2).
The flange surface of the rotary
flange fitting must be upright!
For proper sealing the profile of
the profile flange seal must point
towards the rotary flange fitting
Fig. 4:
Attach and engage appliance
1
Insert screws
2
Turn clockwise to engage screws
Fig. 5:
Connection of appliance
engaged
Do not undo the screws of the device!
1.
Insert the heads of the four flange
screws through the bayonet holes on the
rotary flange fitting (see Figure 4).
2.
Turn the device in clockwise direction up
to the stop (see Figure 4 and Figure 5).
3.
Tighten the four flange screws.
UNIT
Select the tightening torque (approx.
10 Nm) so that the seal is effective
and the device is not damaged or
strained!
1703301 • 2020/07
JUDO JPM-QC
9
Содержание 8165020
Страница 11: ...Installation 3 4 1 Drainage options for the backwash water 1703301 2020 07 JUDO JPM QC 11...
Страница 15: ...When recommissioning the device proceed as with a new installation 1703301 2020 07 JUDO JPM QC 15...