Technical data
7
Technical data
Domestic water station
JUDO PROMI-QC
JPM-QC
The water to be filtered must comply with the European Drinking Water Directive.
Information about:
JPM-QC 1½"
JPM-QC 2"
Pipe connection
1½"
2"
Backwashing volume flow
1)
0
.
3 L/s
0
.
3 L/s
Nominal pressure
PN 16
PN 16
Operating pressure
1
.
5 - 16 bar
1
.
5 - 16 bar
Rated flow acc. to
DIN EN 1567
9
.
1 m³/h
14
.
0 m³/h
Settable downstream pressure
1.5 bar - 6 bar
1.5 bar - 6 bar
Factory setting of downstream
pressure
4 bar
400 kPa
4 bar
400 kPa
Mesh size
2)
sieve insert
100 μm
0.1 mm
100 μm
0.1 mm
Water temperature and ambient
temperature
max. 30 °C
max. 30 °C
Threaded connection according to
DIN EN 10226-1
Weight
17
.
5 kg
18
.
7 kg
Order no.
8150107
8150108
Order no.
3)
- not for DE -
8165020
8165021
1) Applies to a fully opened backwashing valve and 2 - 3 bar (200 - 300 kPa) mains pres-
sure
2) Standard sieve mesh size
Available special sieve mesh sizes (30 μm / 0.03 mm, 320 μm / 0.32 mm and 500 μm /
0.5 mm) for the industrial use are not part of the testing acc. to DIN EN 13443-1 and
DIN 19628 and therefore can not bear the DIN-DVGW mark.
3) With silver-plated sieve insert
18