Powering the V200s
Power
connections
For best performance, use a clean and continuous power supply.
See Table B-
for complete power specifications.
If using an unterminated cable, before powering up the V200s, you must
terminate the wires of the power cable as required. There are a variety of
power connectors and terminals on the market from which to choose,
depending on your specific requirements. Refer to Figure 2-9 and Table
2-4 for pinout specifications.
Do not apply a voltage higher than 36 VDC. The V200s is protected from a
reversed power connection. A 3-Amp power fuse is recommended for the
protection of personnel and the system.
The V200s starts when sufficient voltage is applied to the power leads of
the extension cable.
Electrical
isolation
The V200s’s power supply is isolated from the communication lines and
the PC-ABS plastic enclosure isolates the electronics mechanically from
the vessel (addressing the issue of vessel hull electrolysis).