(a) Display the INSTALLATION menu by pressing the
[MENU]
key in long mode, select
DATA/IN OUT and NMEA OUT and press
[JOG DIAL]
or
[ACQ/ENT]
.
(b) When the following menu is displayed, select the output times to be changed from GGA ,
GLL , RMC , VTG , OSD , RSD , and TTM by turning
[JOG DIAL]
and press
[JOG DIAL]
or
[ACQ/ENT]
.
(c) Set an output frequency by turning
[JOG DIAL]
and end the operation by pressing
[JOG
DIAL]
or
[ACQ/ENT]
.
GGA
0SEC
0SEC
0SEC
RMC
0SEC
VTG
0SEC
OSD
0SEC
RSD
0SEC
TTM
0SEC
CURSOR POS.
OFF
NMEA OUT
Example : Changing GGA output time
Use the following procedure to set the
Use the following procedure to set the
Use the following procedure to set the
Use the following procedure to set the
[CSR POS]
key output to ON or OFF.
key output to ON or OFF.
key output to ON or OFF.
key output to ON or OFF.
(a) Select CURSOR POS. on the menu shown in (b) above and press
[JOG DIAL]
or
[ACQ/ENT]
.
(b) Select OFF or ON by turning
[JOG DIAL]
and end the operation by pressing
[JOG
DIAL]
or
[ACQ/ENT]
.
GGA
0SEC
GLL
0SEC
RMC
0SEC
VTG
0SEC
OSD
0SEC
CURSOR POS.
0SEC
OFF
0SEC
ON
OFF
NMEA OUT
9.8.30 Setting selection of a magnetic azimuth sensor correction value [MENU]
Set whether correction values are set manually or RMC data is used when connecting a magnetic
azimuth sensor.
Select whether correction values are set manually using a magnetic compass or RMC DATA is
used.
Note
When RMC data is set in the following settings and RMC data is not set, 0 degree is assumed for the
correction value.
Use the following procedure to set selection of a magnetic azimuth sensor correction value.
Use the following procedure to set selection of a magnetic azimuth sensor correction value.
Use the following procedure to set selection of a magnetic azimuth sensor correction value.
Use the following procedure to set selection of a magnetic azimuth sensor correction value.
(a) Display the INSTALLATION menu by pressing the
[MENU]
key in long mode, select
DATA/IN OUT , CALIBRATION , and MAG CORR. and press
[JOG DIAL]
or
[ACQ/ENT]
.
Содержание JMA-5104
Страница 1: ...JMA 5104 5106 5110 MARINE RADAR EQUIPMENT INSTRUCTION MANUAL ...
Страница 14: ...IX EQUIPMENT APPEARANCE Scanner Unit Type NKE 2042 2 feet Scanner Unit Type NKE 2062 4 feet ...
Страница 15: ...X Scanner Unit Type NKE 2102 6 feet Processing Unit Type NDC 1260 ...
Страница 16: ...XI Display Unit Type NWZ 146 Landscape and Keyboard Unit NCE 7640 ...
Страница 17: ...XII Display Unit Type NWZ 146 Portrait and Keyboard Unit NCE 7640 ...
Страница 27: ......
Страница 31: ...4 1 4 Configuration Fig 1 1 OUTLINE DRAWING OF SCANNER UNIT NKE 2042 ...
Страница 32: ...5 Fig 1 2 OUTLINE DRAWING OF SCANNER UNIT NKE 2062 ...
Страница 33: ...6 Fig 1 3 OUTLINE DRAWING OF SCANNER UNIT NKE 2102 ...
Страница 34: ...7 Fig 1 4 OUTLINE DRAWING OF PROCESSING UNIT NDC 1260 ...
Страница 35: ...8 Fig 1 5 OUTLINE DRAWING OF KEYBOARD UNIT NCE 7640 ...
Страница 36: ...9 Fig 1 6 OUTLINE DRAWING OF DISPLAY UNIT NWZ 146 LANDSCAPE ...
Страница 37: ...10 Fig 1 7 OUTLINE DRAWING OF DISPLAY UNIT NWZ 146 PORTRAIT ...
Страница 142: ...115 9 2 3 Connection of cables to be assembled 1 Radome scanner unit NKE 2042 ...
Страница 144: ...117 2 Rotary scanner unit NKE 2062 NKE 2102 ...
Страница 145: ...118 ...
Страница 159: ...132 Method of assembling and connecting P3 LTWD06BFFA L180 and P5 LTWD08BFFA L180 that are attached ...
Страница 232: ... Fig 107 INTERNAL CONNECTION OF SCANNER UNIT NKE 2042 ...
Страница 233: ... Fig 108 INTERNAL CONNECTION OF SCANNER UNIT NKE 2062 ...
Страница 235: ... Fig 110 CIRCUIT DRAWING OF MODULATOR UNIT CME 322 ...
Страница 236: ... Fig 111 CIRCUIT DRAWING OF MODULATOR UNIT CME 323 ...
Страница 240: ... Fig 115 INTERNAL CONNECTION OF DISPLAY UNIT NCD 4310 ...
Страница 241: ... Fig 116 CIRCUIT DRAWING OF POWER SUPPLY UNIT CBD 1638 ...