161
(In this state, the echo is displayed at the highest level on this PPI screen.)
(g) Display the INSTALLATION menu by pressing the
[MENU]
key in long mode, select
RADAR , RADAR ADJUST2 , and STC PRESET , and press
[JOG DIAL]
or
[ACQ/ENT]
.
(h) Adjust the control level to the level where noise near 6NM is slightly above by turning
[JOG DIAL]
and end the operation by pressing
[JOG DIAL]
or
[ACQ/ENT]
.
S
S
S
ST
T
T
TC
C
C
C
P
P
P
PR
R
R
RE
E
E
ES
S
S
SE
E
E
ET
T
T
T
0000 0000 6666 3333
9.8.3 Control of main bang [+RANGE-] [AUTO-TUNE] [AUTO-SEA] [AUTO-RAIN]
[GAIN/PL] [MENU]
This adjustment is to suppress a main bang, which is a reflection signal from a microwave circuit
of a waveguide that normally appears as a circular image at the center of the radar screen.
In the optimum adjustment, a faint image of a main bang remains on the screen.
Do not change this adjustment unnecessarily.
An incorrect adjustment may erase the closest target and a collision may occur.
Use the following procedure to set a main bang suppression level and its range.
Use the following procedure to set a main bang suppression level and its range.
Use the following procedure to set a main bang suppression level and its range.
Use the following procedure to set a main bang suppression level and its range.
(a) Set range to 0.125NM by using the
[+RANGE-]
key.
(b) Adjust the tuning using the
[AUTO-TUNE]
knob.
(c) Set the target expansion function to OFF.
(d) Set the correlation processing function to OFF.
(e) Turn
the
[AUTO-SEA]
knob to the center position, and adjust the function strength to the
extent that main bang can be indentified.
(f) Turn
the
[AUTO-RAIN]
knob to the minimum position (anti-clockwise for one full rotation).
(g) Turn
the
[GAIN/PL]
knob to the maximum position (clockwise for one full rotation).
(In this state, the echo is displayed at the highest level on this PPI screen.)
(h) Display the INSTALLATION menu by pressing the
[MENU]
key in long mode, select
RADAR , RADAR ADJUST2 , and MBS LVL , and press
[JOG DIAL]
or
[ACQ/ENT]
.
Содержание JMA-5104
Страница 1: ...JMA 5104 5106 5110 MARINE RADAR EQUIPMENT INSTRUCTION MANUAL ...
Страница 14: ...IX EQUIPMENT APPEARANCE Scanner Unit Type NKE 2042 2 feet Scanner Unit Type NKE 2062 4 feet ...
Страница 15: ...X Scanner Unit Type NKE 2102 6 feet Processing Unit Type NDC 1260 ...
Страница 16: ...XI Display Unit Type NWZ 146 Landscape and Keyboard Unit NCE 7640 ...
Страница 17: ...XII Display Unit Type NWZ 146 Portrait and Keyboard Unit NCE 7640 ...
Страница 27: ......
Страница 31: ...4 1 4 Configuration Fig 1 1 OUTLINE DRAWING OF SCANNER UNIT NKE 2042 ...
Страница 32: ...5 Fig 1 2 OUTLINE DRAWING OF SCANNER UNIT NKE 2062 ...
Страница 33: ...6 Fig 1 3 OUTLINE DRAWING OF SCANNER UNIT NKE 2102 ...
Страница 34: ...7 Fig 1 4 OUTLINE DRAWING OF PROCESSING UNIT NDC 1260 ...
Страница 35: ...8 Fig 1 5 OUTLINE DRAWING OF KEYBOARD UNIT NCE 7640 ...
Страница 36: ...9 Fig 1 6 OUTLINE DRAWING OF DISPLAY UNIT NWZ 146 LANDSCAPE ...
Страница 37: ...10 Fig 1 7 OUTLINE DRAWING OF DISPLAY UNIT NWZ 146 PORTRAIT ...
Страница 142: ...115 9 2 3 Connection of cables to be assembled 1 Radome scanner unit NKE 2042 ...
Страница 144: ...117 2 Rotary scanner unit NKE 2062 NKE 2102 ...
Страница 145: ...118 ...
Страница 159: ...132 Method of assembling and connecting P3 LTWD06BFFA L180 and P5 LTWD08BFFA L180 that are attached ...
Страница 232: ... Fig 107 INTERNAL CONNECTION OF SCANNER UNIT NKE 2042 ...
Страница 233: ... Fig 108 INTERNAL CONNECTION OF SCANNER UNIT NKE 2062 ...
Страница 235: ... Fig 110 CIRCUIT DRAWING OF MODULATOR UNIT CME 322 ...
Страница 236: ... Fig 111 CIRCUIT DRAWING OF MODULATOR UNIT CME 323 ...
Страница 240: ... Fig 115 INTERNAL CONNECTION OF DISPLAY UNIT NCD 4310 ...
Страница 241: ... Fig 116 CIRCUIT DRAWING OF POWER SUPPLY UNIT CBD 1638 ...