54 | Appendix A
4.1.2 Specifications MFL
Box Contents upon Delivery
AlphaLine MFL 3803.0246 grey / 3803.0248 black
Mounting bracket
Screws (4 pcs)
USB flash drive with manuals
Template for cut-outs
Sheet with front stickers
Power Specifications
Power supply
24 VDC input +/- 20% (Single source)
Power consumption
12 W (24 VDC @ 500 mA in rush prox. 4 A)
Protection
Reverse polarity protection
Start-up time
30 sec.
Operating Conditions
Operating temperature
-25°C to +55°C
2
Operating humidity
Up to 95% (at 40°C)
Storage temperature
-25°C to +70°C
Storage humidity
Up to 95% (at 40°C)
IP rating
IP56 front / IP22 back
Compass safe distance
Std: 0.1m / Steering: 0.1m
Environmental according to DNV 2.4 table 2.1
Temperature
Class D
Humidity
Class B
Vibration
Class A
EMC compatibility
Class B
Enclosure
Class C
Display Functionality
Font display text
7 mm (viewing distance = 2 m)
Font operation buttons
3.5 mm (viewing distance = 1 m)
Accuracy
Resolution 0.1°/min
Acoustic noise level
0 db
Display Specifications
High quality TFT
Touch screen 8.4"
Pixels
800 x 600 (aspect ratio 4:3)
Orientation
Horizontal
Light intensity
Max. brightness 450 cd/m2
View angle (H/V)
140°/180°
Maximum colors
16.7 million
Input/Output Signals
COM 0 (IEC 61162-2) isolated
Modbus RTU Rx/Tx
COM 1 (IEC 61162-1) isolated
NMEA Rx/Tx
COM 2 (IEC 61162-1) isolated
NMEA Rx/Tx
COM 3 (IEC 61162-1) isolated
NMEA Rx/Tx
USB port (Mini)
Used for software update/maintenance
Alarm output
NOC contact (potential free)
Norms/Standards
IEC 60945 (2002)
Incl. IEC 60945 Corrigendum 1 (2008)
Standard DNV 2.4
Det Norske Veritas
IEC 61162 series
NMEA Definitions
IEC 62288 (2014)
Testing methods
4.1.3 Available Accessories
Available Accessories
MFL IP56 Kit
3698.0020
MFM IP56 Kit
3698.0018
Table 14: Available Accessories
2
Although the test conditions for bridge units provide for a maximum operation temperature of 55°C, continuous operation of all electronic components should, if
possible, take place at ambient temperature of 25°C. This is necessary for a long life and low service costs.
Содержание AlphaWind AlphaLine MFL
Страница 1: ...AlphaWind Wind Repeater Installation and Operation Manual www jrc am ...
Страница 29: ...29 Operation Figure 21 Alert Handling in Menu example ...
Страница 56: ...56 Appendix A 4 3 Mechanical Drawings 4 3 1 Mechanical Drawing MFM Figure 51 Mechanical Drawing MFM ...
Страница 57: ...57 Appendix A 4 3 2 Mechanical Drawing MFL Figure 52 Mechanical Drawing MFL ...
Страница 59: ...59 Appendix A 4 4 2 Connection Diagram AlphaWind Figure 54 Connection Diagram AlphaWind 1 ...
Страница 60: ...60 Appendix A Figure 55 Connection Diagram AlphaWind 2 ...
Страница 62: ...62 Appendix A 4 5 1 Schematics AlphaLine MF Display Unit Figure 56 Schematics AlphaLine MF Display Unit ...
Страница 63: ...63 Appendix A 4 5 2 Schematics AlphaLine Instrument Figure 57 Schematics AlphaLine Instrument ...