15 | Installation Instructions
Figure 8: Grounding Bolt
Note The grounding strap must be as short as possible. If wire is used, use a minimum of 2.5 mm
2
copper wire.
See Figure 8: Grounding Bolt on page 15.
Note Always check the drawing for the correct shielding of signals.
1.1.10 Instrument Power Supply
The AlphaLine instrument has one 24 VDC (nominal) power input. Power consumption is approx. 500 mA. Connect to a
power supply > 1 A.
Note The power supply input is protected against connecting to the wrong polarity.
Note In rush current approximately 4 A.