XP70 Instruction Manual
The XP70 offers two different types of Gyro Sensitivity
Adjustments — manual or automatic. This feature gives
the user the choice of selecting gyro sensitivity manually
through the rudder dual rate switch or automatically
through the flight mode switch.
In function mode press the
UP
or
Down
key until
GYRO
SENS
screen appears on the screen.
Use the
Select
key to highlight the desired rate or
flight mode.
Press the
IncreaSe
or
DecreaSe
key to change
the rate value or the select position 0 or 1 for each
flight mode.
Gyro Sensing
Manual Gyro Sensitivity Adjustment
Manual Gyro Sensitivity Adjustment allows the pilot to
select from two different gyro sensitivities during all flight
conditions. This function is activated in conjunction with
the rudder dual rate switch.
Automatic Gyro Sensitivity Adjustment
The Automatic Gyro Sensitivity Adjustment feature allows
the pilot to automatically alter the sensitivity of the gyro
from either of two pre-determined settings through the
use of the flight mode switch. As different flight modes are
selected (Normal, 1, , Hold), the Gyro’s sensitivity rate
will switch to the pre-determined compensation rate for
each particular flight mode in use.
[GYRO SENS]
◊RUDD
RATE:
0: 50%
1: 50%
Press to enter
Function Mode
Press to enter GYRO SENS
Press to select
desired channel
Press to return
value to default