CAUTION
This device is intended for adult use in homes only.
The device is not suitable for use on neonatal patients, pregnant women, patients with implanted,
electronical devices, patients with pre-eclampsia, premature ventricular beats, atrial fibrillation,
peripheral, arterial disease and patients undergoing intravascular therapy or arterio-venous shunt or
people who received a mastectomy. Please consult your doctor prior to using the unit if you suffer from
illnesses.
The device is not suitable for measuring the blood pressure of children. Ask your doctor before using it
on older children.
The device is not intended for patient transport outside a healthcare facility.
The device is not intended for public use.
This device is intended for no-invasive measuring and monitoring of arterial blood pressure. It is not
intended for use on extremities other than the arm or for functions other than obtaining a blood pressure
measurement.
Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood pressure.
Do not begin or end medical treatment without asking a physician for treatment advice.
If you are taking medication, consult your physician to determine the most appropriate time to measure
your blood pressure. Never change a prescribed medication without consulting your physician.
Do not take any therapeutic measures on the basis of a self measurement. Never alter the dose of a
medicine prescribed by a doctor. Consult your doctor if you have any question about your blood pressure.
When the device was used to measure patients who have common arrhythmias such as atrial or
ventricular premature beats or atrial fibrillation, the best result may occur with deviation. Please consult
your physician about the result.
Don’t kink the connection tube during use, otherwise, the cuff pressure may continuously increase which
can prevent blood flow and result in harmful injury to the PATIENT.
When using this device, please pay attention to the following situation which may interrupt blood flow
and influence blood circulation of the patient, thus cause harmful injury to the patient: connection
tubing kinking too frequent and consecutive multiple measurements; the application of the cuff and
its pressurization on any arm where intravascular access or therapy, or an arterio-venous (A-V) shunt, is
present; inflating the cuff on the side of a mastectomy.