Editing the chosen data group

 

To edit the chosen data group press V/↑ or A/↓ to navigate upwards  

 

or downwards through the menu options. Press the rotary switch  

 

and the selected numerical value will be highlighted with the cursor.  

 

More actuations of the rotary switch will lead to scrolling through  

 

the possible characters. After the desired value is selected, hold    

 

down SET until the number of the data group is shown on the right  

 

side of the screen. The value of the data will now be saved in the   

 

selected data group. By pressing SET again, you return to the menu.  

 

You can leave the menu by pressing SET again. 

 

Status of the selected data group at the start of the device

 

You can configure the device to automatically activate the output  

 

when the device is turned on. Navigate to do this in the 

S-INI

 option  

 

and set the value to 

ON

 to activate the option. Once you have  

 

 

selected the desired setting, press and hold the SET button until the

 

data group number is displayed on the right side of the screen.    

 

The data value is now stored. Press the Set button again to return to  

 

the previous menu. To exit the menu, press the Set button again.

Activating and deactivating the ouput

You can press the ON/OFF button to activate or deactivate the output at any 

time. 

Key lock

The keys can be deactivated to avoid unintentional changes. You can hold 

the rotary switch longer than 3 seconds to block the keys or to unlock them 

again at any time . The status of the key lock is shown with the lock symbol 

on the right side of the screen. 

Содержание DPS5015

Страница 1: ...ed in 0 01A steps The power supply is additionally equipped with a switch off parameter memory and ten programmable data memories The operation of the device has been optimized for particularly easy o...

Страница 2: ...crew terminals Input voltage Output voltage Output current Output power Weight Display size Display module size Power module size Accuracy of output voltage Accuracy of output current 6 60 V 0 50 V 0...

Страница 3: ...voltage In addition always ensure sufficient ventilation of the device for heat dissipation The permissible range of the input voltage is 6 60 V DC Always ensure a sufficient safety distance and neve...

Страница 4: ...lue Input voltage Limit of output current Lock enlock keys Normal abnormal status Constant voltage current Number of data group Active inactive output Preset output voltage Preset limit of output curr...

Страница 5: ...ding to your requirements You can then use the SET button to return to the menu options Press the SET button again to exit the menu Setting the protection values Navigate through the menu to go to the...

Страница 6: ...switch After that rotate the switch to choose the data group by its number which you want to edit Press it again to change the status of the option M PRE By activating this option the output stays the...

Страница 7: ...e device You can configure the device to automatically activate the output when the device is turned on Navigate to do this in the S INI option and set the value to ON to activate the option Once you...

Страница 8: ...used batteries and accumulators which are not enclosed by the device Return options As the end user you can hand over with the purchase of a new device your old appliance which has essentially the sa...

Отзывы: