4. PANEL AND DISPLAY

After the first start, the welcome screen is displayed, followed by the main 

screen. The main screen displays selected voltage and current limits. 

When the output is active, the current actual values are also displayed. 

On the right side of the screen there are icons and prompts that indicate 

the system status. For a detailed description of the display, refer to the 

following diagram.

Attention!

 Make sure that the input voltage is always at least 1.1 

times the output voltage. In addition, always ensure sufficient 

ventilation of the device for heat dissipation.

The permissible range of the input voltage is 6 - 60 V (DC).

 

Always ensure a sufficient safety distance and never exceed the 

maximum permissible input voltage. Non-observance can cause 

substantial damage at your device. 

Operate the device exclusively with direct current! 

Operating 

the device with alternating current can lead to fatal electric 

shocks and irreparable damage to the device.

Voltage settings, arrow 

upwards, M1 data group

Data input, 

extract / save 

data from / 

in data group

Current settings, arrow  

downwards, M2 data group

1,44“ LCD-Display
Rotrary switch, 

key lock

Activate / deactivate 

output

Содержание DPS5015

Страница 1: ...ed in 0 01A steps The power supply is additionally equipped with a switch off parameter memory and ten programmable data memories The operation of the device has been optimized for particularly easy o...

Страница 2: ...crew terminals Input voltage Output voltage Output current Output power Weight Display size Display module size Power module size Accuracy of output voltage Accuracy of output current 6 60 V 0 50 V 0...

Страница 3: ...voltage In addition always ensure sufficient ventilation of the device for heat dissipation The permissible range of the input voltage is 6 60 V DC Always ensure a sufficient safety distance and neve...

Страница 4: ...lue Input voltage Limit of output current Lock enlock keys Normal abnormal status Constant voltage current Number of data group Active inactive output Preset output voltage Preset limit of output curr...

Страница 5: ...ding to your requirements You can then use the SET button to return to the menu options Press the SET button again to exit the menu Setting the protection values Navigate through the menu to go to the...

Страница 6: ...switch After that rotate the switch to choose the data group by its number which you want to edit Press it again to change the status of the option M PRE By activating this option the output stays the...

Страница 7: ...e device You can configure the device to automatically activate the output when the device is turned on Navigate to do this in the S INI option and set the value to ON to activate the option Once you...

Страница 8: ...used batteries and accumulators which are not enclosed by the device Return options As the end user you can hand over with the purchase of a new device your old appliance which has essentially the sa...