2. TECHNICAL DETAILS

Connect the display module with the included cables to the 

according LCD and Key interfaces. The next step is the connection of the 

inputs and outputs via screw terminals.

Input voltage

Output voltage

Output current

Output power

Weight

Display size

Display module size

Power module size

Accuracy of 

output voltage

Accuracy of 

output current

6 - 60 V

0 - 50 V

0 - 15 A

0 - 750 W

152 g

1,44“

80 x 42 x 45 mm

40 x 67 x 91 mm

± 0,5 %

± 0,5 %

3. CONNECTION DETAILS

IN +

IN -

OUT +

OUT -

IN + 

IN - 

OUT +

OUT -

Positive input

Negative input

Positive output

Negative output

Содержание DPS5015

Страница 1: ...ed in 0 01A steps The power supply is additionally equipped with a switch off parameter memory and ten programmable data memories The operation of the device has been optimized for particularly easy o...

Страница 2: ...crew terminals Input voltage Output voltage Output current Output power Weight Display size Display module size Power module size Accuracy of output voltage Accuracy of output current 6 60 V 0 50 V 0...

Страница 3: ...voltage In addition always ensure sufficient ventilation of the device for heat dissipation The permissible range of the input voltage is 6 60 V DC Always ensure a sufficient safety distance and neve...

Страница 4: ...lue Input voltage Limit of output current Lock enlock keys Normal abnormal status Constant voltage current Number of data group Active inactive output Preset output voltage Preset limit of output curr...

Страница 5: ...ding to your requirements You can then use the SET button to return to the menu options Press the SET button again to exit the menu Setting the protection values Navigate through the menu to go to the...

Страница 6: ...switch After that rotate the switch to choose the data group by its number which you want to edit Press it again to change the status of the option M PRE By activating this option the output stays the...

Страница 7: ...e device You can configure the device to automatically activate the output when the device is turned on Navigate to do this in the S INI option and set the value to ON to activate the option Once you...

Страница 8: ...used batteries and accumulators which are not enclosed by the device Return options As the end user you can hand over with the purchase of a new device your old appliance which has essentially the sa...