background image

Hearth-mount  into a  Masonry Fireplace

The OSLO F500 may be installed into a masonry

fireplace  provided  the  height  of  the  opening  is  a

minimum of 29”.  The short leg package reduces the

stove’s height by 2 1/4”.

When  installing  the  OSLO  F500  into  a  masonry

fireplace, code requires that the fireplace damper plate

be removed or securely fixed in the open position.  A

connector pipe must then extend from the stove’s flue

exit through the damper area of the fireplace and into

the chimney tile liner. 

See figure 5

The inside area of the flue liner must not be less than

the area of the stove’s flue exit, and cannot be more

than three times greater than the cross sectional area

of the stove’s flue exit.

If the chimney liner is too large to accommodate the

stove, an approved relining system must be installed

to resize the flue.

A new sheet metal damper block-off plate must be

installed around the connector pipe at the damper

frame and sealed with the proper sealant (usually

High-Temp Silicone).

Fireplace installation must also observe the proper

clearances to surrounding trim and mantels (addressed

in clearance section of this manual).  In addition,

fireplace installations must also adhere to the floor

protection guidelines specified in the following section.

Prefabricated Chimneys

When installing the OSLO F500 to a prefabricated

metal chimney always follow the pipe manufacture’s

instructions and be sure to use the components that

are required.  This usually includes some type of

“smoke pipe adapter” that is secured to the bottom

section of the metal chimney and allows the chimney

pipe to be secured to it with three sheet metal screws.

                                         

 See figures 6 and 7

8

FIGURE 6

FIGURE 7

DAMPER  OPENING  IS

SEALED  WITH  SHEETMETAL

PLATE AND  SEALANT

CONNECTOR  EXTENDS

TO  FIRST  FLUE  TILE

FIGURE 5

Содержание Oslo F 500

Страница 1: ...instructions for future reference Avis de s curit Une installation non appropri e de ce po le de chauffage risque de provoquer un incendie Assurez votre s curit en respectant les directives d installa...

Страница 2: ...tallations 10 Mobile Home Installations 10 Operation 13 Controls 13 Breaking in your Stove 13 Starting Maintaining 14 Formation of Creosote 14 Maintenance 15 Ash Removal 15 Glass Care 15 General Maint...

Страница 3: ...lways consult your local building inspector or authority having jurisdiction to determine what regulations apply in your area NOTICES BE SURE TO READ THIS ENTIRE MANUAL BEFORE YOU INSTALL OR USE YOUR...

Страница 4: ...h no more than two 90 elbows The maximum horizontal run is 36 and a recommended total length of stove pipe should not exceed 10 feet Always slope horizontal runs upward per foot toward the chimney No...

Страница 5: ...of the chimney 5 CHIMNEY REQUIREMENTS There are two types of chimneys suitable for the OSLO F500 1 A code approved masonry chimney with a flue liner 2 A prefabricated chimney complying with the requir...

Страница 6: ...rick with a minimum of 3 thick 4 nominal Refractory mortar must be used at the junction of the chimney and the pass through liner The pass through liner must not penetrate the chimney liner beyond the...

Страница 7: ...nspector authorized J tul Dealer NFPA 211 in the U S or CAN CSA B635 in Canada for other approved wall pass through methods CONNECTING TO THE CHIMNEY Masonry Chimney When installing a OSLO F500 into a...

Страница 8: ...ust be installed to resize the flue A new sheet metal damper block off plate must be installed around the connector pipe at the damper frame and sealed with the proper sealant usually High Temp Silico...

Страница 9: ...can burn i e sheet rock wall paper wood fabrics etc These surfaces are not limited to those that are visible and also include materials that are behind non combustible materials If you are not sure o...

Страница 10: ...ceiling height off the top of the stove in a protected ceiling installation is 15 380mm 7 ALCOVE floor protection must be a UL ULC or WHI listed hearth pad or a non combustible materialwithaminimumRv...

Страница 11: ...PARALLEL TO THE WALL UNPROTECTED SURFACE CORNER INSTALLATION PROTECTED SURFACE PER NFPA 211 CORNER INSTALLATION IMPORTANT CONNECTOR HEATSHIELDS AND DOUBLE WALL PIPE MUST BE A LISTEDPRODUCT ALWAYS FOLL...

Страница 12: ...PROTECTED SURFACE NFPA 211 CLEARANCES pipe VERTICAL INSTALLATION VERTICAL INATALLATION Single wall 18 12 with no heatshields 460mm 300mm Single wall 6 6 with connector shields 150mm 150mm Double wall...

Страница 13: ...Breaking in your new stove Your new OSLO F500 is constructed of cast iron and stove furnace cement This type of construction requires the stove to be broken in gradually so that heat expansion does n...

Страница 14: ...FYOUNOTICETHISCONDITION Adding Fuel When reloading the stove while it is still hot and a bed of hot embers still exist follow this reloading procedure Always wear gloves when tending to the stove Push...

Страница 15: ...roper cleaning procedure is as follows 1 Glass needs to be COMPLETELY COOL 2 Only use a cleaner that is specifically designed for this purpose The use of abrasives will damage the glass and ultimately...

Страница 16: ...been approved for use as an open fireplace with front door open This feature is especially nice when the ambience of a fire is desired Some care should be taken when operating the stove as a fireplac...

Страница 17: ...Heatshield part 154332 A stove rear heatshield has been specifically designed for the OSLO F500 to reduce clearances off the rear of the stove to combustible materials Use of the heatshield DOES NOT a...

Страница 18: ...ED VIEW OF THE OSLO F500 ONLY USE REPLACEMENTS PARTS PROVIDED THROUGH YOUR AUTHORIZED J TUL DEALER 18 19 18 17 14 16 15 20 22 23 24 21 25 26 27 28 29 34 30 31 33 32 29 1 2 3 4 5 6 7 8 9 10 11 12 13 41...

Страница 19: ...f C 1 25 therefore R brick 1 C 1 1 25 0 80 1 8 mineral board of k 0 29 therefore R mineral board 1 29 X 0 125 0 431 Total R R brick R mineral board 0 8 0 431 1 231 Step C Compare proposed system R 1 2...

Страница 20: ...ue a policy of constant product development Products supplied may therefore differ in specification colour and type of accessories from those illustrated and described in the brochure J tul vise sans...

Отзывы: