Jøtul GF 300 BV Скачать руководство пользователя страница 5

5

137945_Rev_F   7.29.10

General Information

 

THIS HEATER MUST BE INSTALLED AND MAINTAINED 

BY A QUALIFIED SERVICE AGENCY. 

 

 

The installation and repair of this appliance must be 

done by a qualified service person.  Failure to properly 

install and maintain this heater could result in an 

unsafe or hazardous installation, which may result in 

a fire, explosion, property damage, personal injury or 

loss of life. 

 

This appliance may be installed in an aftermarket 

permanently located, manufactured (mobile) home, 

where not prohibited by local codes.

  This appliance is only for use with the type(s) of gas 

indicated on the rating plate. This appliance is not 

convertible for use with other gases, unless a certified 

kit is used.

  Cet appareil peut être installé dans un maison préfab-

riquée (mobile) déjà installée à demeure si les règle-

ments locaux le permettent.

  Cet appareil doit être utilisé uniquement avec les 

types de gas indiqués sur la plaque signalétique. Ne 

pas l’utiliser ave d’autres gas sauf si un kitde conver-

sion certifié est installé.

 

This appliance should be inspected before use and 

at least annually.  More frequent cleaning may be 

required due to excessive lint from carpeting, bedding 

material, etc.  It is imperative that control compart-

ments, burners, and circulating air passageways of 

the appliance be kept clean.

 

THIS APPLIANCE MUST NOT BE CONNECTED TO A 

CHIMNEY OR FLUE SERVING ANY OTHER APPLIANCE.

 

The installation must conform to local codes.  Your lo-

cal Jøtul dealer can assist you in determining what is 

required in your area for a safe and legal installation.  

Some areas require a permit to install a gas burning 

appliance.  Always consult your local building inspec-

tor, or authority having jurisdiction, to determine 

what regulations apply in your area.  

 

CODE COMPLIANCE:  Your local officials have final 

authority in determining if a proposed installation is 

acceptable.  Any requirement that is requested by the 

local authority having jurisdiction, that is not specifi-

cally addressed in this manual, defaults to local code.  

In the absence of local codes, the installation re-

quirements must comply with the current edition of 

National codes.  In the U.S., these requirements are es-

tablished in the National Fuel Code, ANSI Z223.1.(NFPA 

54) current edition.  In Canada, the codes have been 

established in CAN/CGA B149 Fuel Installation Code, 

current edition.

Glass Panel

Do not operate this appliance with the glass 

front removed, cracked, or broken.  Replacement  

of the glass should be done by a licensed or 

qualified service person.  Only remove glass for 

routine service.  Always handle glass carefully.

  Consult the local or national installation code(s) to 

assure that adequate combustion and ventilation air is 

available.

 

Installer l’appareil selon les codes ou reglements 

locaux, ou, en l’absence de tels reglements, selon les 

Codes d’installation CAN/CGA-B149.

 

DO NOT OPERATE THIS STOVE IF ANY PART HAS BEEN 

UNDER WATER. 

 Call a qualified service technician to 

inspect the heater and to replace any part of the con-

trol system and any gas control which may have been 

under water.

 

Ne pas se servir de cet appareil s’il a ete’ plonge dans 

l’eau, completement ou en partie.  Appeler un tech-

nicien qualifie pour inspecter l’appareil et remplacer 

toute partie du syste’me de controle et toute com-

mande qui ont ete plonges dans l’eau.

Hardware Bag Contents

•  Fuel Conversion Kit - LP ...................................155592
*  Decorative Pipe Brackets  ...............................129469

Unpacking your stove 

1.  Remove the Top Plate of the stove by simply lifting it 

straight off of the stove body.

2.  To open the firebox, disengage the two Glass Frame 

Latches located on top of the firebox. Pull each handle 

forward to clear the latch from the notch in the frame. 

3.  Familiarize yourself with the installation requirements 

specified in this manual, before beginning the installa-

tion.

Glass Frame 

Latch

Содержание GF 300 BV

Страница 1: ...or future reference QUEFAIRESIVOUSSENTEZUNEODEURDEGAZ Ne pas tenter d allumer l appareil Ne touchez aucum interrupteur Ne pas vous servir des t l phones se trouvant dans le b timent o vous trouvez App...

Страница 2: ...stalled and serviced by professionals who are certified in the U S by the National Fireplace Institute NFI as NFI Gas Specialists THIS PRODUCT MUST BE INSTALLED BY A LICENSED MASTER OR JOURNEYMAN PLUM...

Страница 3: ...tion 23 Illustrated Parts Breakdown 24 Replacement Parts List 25 Warranty Statement 26 Lighting Instructions 27 J tul GF BV Allagash Natural Vent Gas Stove 300 Manufactured and Distributed by J tul No...

Страница 4: ...a Propane 12 0 WC 2 99 kPa 14 9 WC 3 71 kPa Manifold Pressure MIN MAX Natural Gas 1 2 WC 30 kPa 3 8 WC 95 kPa Propane 2 9 WC 722 kPa 11 0 WC 2 74 kPa Piezo Ignitor Standing Pilot 13 330 mm Rear Exit 2...

Страница 5: ...thority in determining if a proposed installation is acceptable Any requirement that is requested by the local authority having jurisdiction that is not specifi cally addressed in this manual defaults...

Страница 6: ...ation Due to the high operating temperatures this appliance should be located out of traffic and away from furniture draperies etc Maintain proper clearance to combustible mantels and fireplace trim C...

Страница 7: ...turer s instructions and within the terms of their listing Refer to the manufacturer s instructions for approved clearances from the vent pipe to combustible materials Minimum Alcove Dimensions Mainta...

Страница 8: ...through a roof must have a flashing storm collar thimble and a Type B cap is required See diagrams page 10 Venting on the Allagash CANNOT be less than 4 in diameter or greater than 4 in diameter Any...

Страница 9: ...When installing at an altitude above 2000 the mini mum vertical rise becomes 12 from the draft hood Figure 6 GF 300 BV venting through a masonry chimney Listed termi nation cap required Storm collar...

Страница 10: ...ion cap required NOTE Installation at altitude greater than 2000 re quires minimum 12 ft vertical rise from Draft Hood NOTE Installation at altitude greater than 2000 re quires minimum 12 ft vertical...

Страница 11: ...TH THE REQUIREMENTS OF THE PRO VINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1 B149 1 AND 2 INSTALLATION CODE AVERTISEMENT CET EQUIPEMENT DE CONVERSION SERA...

Страница 12: ...e rear of the firebox When correctly positioned there will be 1 2 13 mm clearance be tween the burner plate and the front of the firebox See fig 15 11 CHANGE THE PILOT ORIFICE From within the firebox...

Страница 13: ...Install the identification labels to the stove so that they can be seen by any person that may be ser vicing the stove Label A apply to back of stove Label B apply to stove s rating plate Small valve...

Страница 14: ...2 0 14 9 The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing on that system at test pressures in excess of 1 2 psig 3 5 kP...

Страница 15: ...Left Log Figure 23 Install Middle Log Figure 24 Position embers loosely and maintain 1 4 clearance from the burner skirt edges 1 4 6 mm 1 4 6 mm Pilot Assembly KEEP CARRY OVER PORTS CLEAR PN 220727 P...

Страница 16: ...ssory wiring diagram Flame Appearance Air Shutter Adjustment The GF 300 BV gas stove is shipped from the factory equipped to burn Natural gas If the stove has been converted for use with propane the A...

Страница 17: ...ated in the center of the valve face Fire intensity can be adjusted up to 50 between the LOW and HIGH settings See fig 29 NO SMOKE OR SOOT SHOULD BE PRESENT CHECK LOG PLACEMENT IF ANY SOOT OR SMOKE IS...

Страница 18: ...ure the stove is cold and there are NO hot embers 5 This appliance has a continuous burning pilot flame Exercise caution when using products having combus tible vapors Always shut off gas supply while...

Страница 19: ...e Compartment Convection Airways and optional Blower to BE CERTAIN THAT THE FLOW OF COMBUSTION AND VENTILATION AIR IS UNOBSTRUCTED The firebox should be vacuumed annually to remove any surface build u...

Страница 20: ...using the two M6 hex nuts and a 10 mm wrench See fig 34 3 Attach the Blower to the stove with the screen open ing to the rear using the two M6 flange head hex bolts as shown in fig 35 4 Attach either...

Страница 21: ...on is not desired place the blower control switch in the MANUAL position M6 x 20 mm Hex Bolts Male Quickconnector Female Figure 35 Attach Blower to the stove bottom and connect wires to Snapstat and f...

Страница 22: ...ck wall resting on the burner skirt Fig 40 5 Install a Side Panel Tilt the panel bottom edge first into position against the side wall The panel will stand on its own against the wall fitting snugly b...

Страница 23: ...equipe ment L installation n est pas propre et complete jusqu a l operation de l appareil converti est cheque suivant les criteres etablis dans les instructions de proprietaire provi sionnees avec l...

Страница 24: ...10 Figure 44 GF 300 BV Allagash Illustrated Parts Breakdown NOTE Models beginning at Serial No 30000 are configured with a front mounted gas control valve ONLY USE REPLACEMENT PARTS PROVIDED BY AN AUT...

Страница 25: ...960 64 Glass Frame 22076292 65 Glass Gasket Tadpole 129124 Replacement Glass Kit 155599 66 Firebox Heat Exchanger 221192 67 Screw 8 x 1 2 Blk 117917 68 Nut M6 Flange 2 117968 69 Exhaust Baffle 220763...

Страница 26: ...osts associated with the repair of gas controls plumbing burners log set or sheet metal firebox beyond the warranty period 5 Damage caused by unauthorized modification use or repair 6 Damage to enamel...

Страница 27: ...knob Never use tools If the knob will not push in or turn by hand do not try to repair it Call a qualified technician Force or attempted repair may result in a fire or explosion D Do not use this appl...

Страница 28: ...ginning the installation it is important that the these instructions be carefully read and understood J tul maintains a policy of continual product development Consequently products may differ in spec...